7DEOH0HVVDJH￿￿￿￿6\VWHP&DXVH0HVVDJHVFRQWLQXHG&RUUHFWLYH$FWLRQ

Unexpected

Faulty or improperly

interrupt in

seated DIMM,

protected

DIMMs not installed

mode

in sets of four, a

 

faulty or improperly

 

seated memory

 

module, or a defec-

 

tive system board

Be sure that the DIMMs are installed in sets of four and in the proper sockets for each mem- ory bank in use. If this does not resolve the problem, remove and reseat the DIMMs and then the memory mod- ule. If the problem persists, replace the DIMMs or the memory module. If the problem still persists, replace the system board.

Unsupported

Microprocessor not

Install a correct version

CPU detected

supported by

of the microprocessor in

in SLOT n

system

the specified micropro-

 

 

cessor connector.

 

 

 

Unsupported

Microprocessor not

Upgrade the BIOS.

CPU speed in

supported by BIOS

 

CMOS

 

 

 

 

 

Warning:

Some portion of

Reflash the system firm-

Firmware is

system firmware is

ware from the Dell

out-of-date,

out of date, possibly

Server Assistant CD (if

please

as result of power

available) or from the

update...

being removed from

Dell World Wide Web

 

the system while

site (www.dell.com).

 

servicing the bat-

 

 

tery, PSPB, system

 

 

board, or SCSI

 

 

backplane.

 

 

 

 

Write fault

Faulty diskette or

Replace the diskette or

 

hard-disk drive

hard-disk drive.

Write fault

 

 

on selected

 

 

drive

 

 

 

 

 

3-12 Dell PowerEdge 6350 Systems Service Manual

Page 56
Image 56
Dell 6350 manual Cmos