7DEOH￿%￿￿￿￿￿&RQILJXUDWLRQ￿8WLOLW\￿0HVVDJHV

0HVVDJH

3UREDEOH￿&DXVH

&RUUHFWLYH￿$FWLRQ

 

 

 

Out of

memory

Either of these messages

Memory allocation

can appear if the system

failed

 

runs out of memory dur-

 

 

ing operation of the

 

 

utility.

Disable any TSR programs or any unneeded device drivers.

Not enough memory

This message appears

to run the ICU

when you start the ICU if

 

the system does not

 

have enough memory to

 

run the utility.

Can’t open index file. This file is required for ICU to run.

The ICU cannot find the index file for its database.

Make sure to switch to drive A before attempting to start the utility.

No Configuration

The device driver needed

Verify that the following device statement appears

Manager.

by the ICU is corrupted or

in your config.sys file:

 

is not correctly

 

 

 

configured.

device=drive:\directory\driv-

 

 

ers\dos\dwcfgmg.sys

 

 

In this statement, drive and directory repre-

 

 

sent the drive and directory where the driver

 

 

resides. The default is c:\plugplay.

 

 

 

At least one Plug

The Configuration Man-

You must reconfigure the conflicting card(s). To

and Play card in

ager or the ICU cannot

find the conflicting card, perform the following

your system is not

configure at least one

steps:

configured due to

Plug and Play expansion

 

 

conflicts. These

card because of resource

￿￿ 6HOHFW￿WKH￿3OXJ￿DQG￿3OD\￿H[SDQVLRQ￿FDUG￿

are marked “config

conflicts with one or

 

PDUNHG￿ZLWK￿config err￿￿DQG￿WKHQ￿FOLFN￿

err” in the list of

more cards.

 

WKH￿0RGLI\￿EXWWRQ￿

configured cards.

 

 

 

 

 

Due to conflicts,

 

 

The Card Configuration dialog box displays the

 

 

functions assigned to the Plug and Play expan-

the ICU could only

 

 

sion card.

configure some Plug

 

 

 

 

 

and Play cards in

 

￿￿

6HOHFW￿D￿IXQFWLRQ￿DQG￿WKHQ￿FOLFN￿6HWWLQJV￿￿

your system. Un-

 

 

 

&OLFN￿&DQFHO￿LI￿WKH￿,&8￿GRHV￿QRW￿GLVSOD\￿D￿

configured cards

 

 

 

 

PHVVDJH￿QDPLQJ￿WKH￿FRQIOLFWLQJ￿FDUG￿

are marked “config

 

 

 

 

 

err” in the list of

 

￿￿

5HSHDW￿VWHS￿￿￿XQWLO￿WKH￿,&8￿GLVSOD\V￿D￿

 

 

configured cards.

PHVVDJH￿ER[￿QDPLQJ￿WKH￿FRQIOLFWLQJ￿

 

 

FDUG￿DQG￿WKH￿UHVRXUFH￿V￿￿LQ￿FRQIOLFW￿￿6HH￿

 

WKH￿IROORZLQJ￿WDEOH￿HQWU\￿IRU￿DQ￿H[SODQD￿

 

WLRQ￿RI￿WKLV￿PHVVDJH￿ER[￿

 

 

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the online System User’s Guide.

B-2 Dell OptiPlex GX1 and GX1p Mini Tower Managed PC Systems Reference and Installation Guide

Page 142
Image 142
Dell GX1 P manual 7DEOH%&RQILJXUDWLRQ8WLOLW\0HVVDJHV, WKH0RGLI\EXWWRQ, Wlrqriwklvphvvdjher