64 Configuration: About Your Storage Array
In-Band Management
Using in-band-management, commands, events, and data travel through the
host-to-controller interface. Unlike out-of-band management, commands
and events are mixed with data.
NOTE: For detailed information on setting up in-band and out-of-band management
see the Deployment Guide.
When you add storage arrays by using this management method, you need to
specify only the host name or IP address of the host. After you add the
specific host name or IP address, the host-agent software automatically
detects any storage arrays that are connected to that host.
CAUTION: Some operating systems can be used only as storage management
stations. For more information about the operating system that you are using, refer
to the MD PowerVault Support Matrix at support.dell.com/manuals.
For more information, see the PowerVault Modular Disk Storage Manager
online help topics.
Access Virtual Disk
Each RAID controller module in an MD3200i Series storage array maintains a
special virtual disk, called the access virtual disk. The host-agent software uses
the access virtual disk to communicate management requests and event
information between the storage management station and the RAID
controller module in an in-band–managed storage array. The access virtual
disk is not available for application data storage. The default LUN is 31.

Storage Arrays

You must add the storage arrays to MDSM before you can setup the storage
array for optimal use.

Adding Storage Arrays

You can add storage arrays only in the EMW. You can:
Automatically discover storage arrays
Manually add storage arrays
NOTE: Verify that your host or management station network configuration—
including station IP address, subnet mask, and default gateway—is correct before
adding a new storage array using the Automatic option.
book.book Page 64 Wednesday, May 26, 2010 2:14 PM