6

Troubleshooting

To get help with your Dell Shared PowerEdge RAID Controller Shared (PERC) 8 card, you can contact your Dell Technical Service representative or see dell.com/contactdell.

Performance variations between write-back and write- through cache modes

Performance is highly variable across configurations, drive type, applications and IO workloads. The write performance of write-through mode is typically lower than that of write-back mode. Some configurations and workloads exhibit significant performance deltas.

Evaluate your needs for maximum I/O performance (a single Shared PERC 8 configuration) versus maximum data protection (a Fault Tolerant Shared PERC 8 configuration).

Shared PERC 8 Card Boots Into Safe Mode

In the event of some failure conditions encountered at boot, Shared PERC 8 boots with restricted capability in safe mode without user intervention. In such a condition Shared PERC 8 reports all configured disk drives as Foreign to the management application. The Dell Chassis Management Controller (CMC) displays events generated by the Shared PERC 8 card indicating the reason for booting into safe mode. The following table details the conditions and the corresponding event notifications that are reported to the CMC.

Table 2. Conditions and the Corresponding Event Notifications Reported to the CMC

Category

Event Reported To the CMC

Description of the

Corrective Action

 

 

Failure

 

 

 

 

 

Pinned

Controller cache pinned

The Shared PERC 8 card

You can restore the

Cache

for missing or offline

preserves dirty cache for

preserved cache to the

 

VDs: %s

a virtual disk that

virtual disk once the

 

 

transitioned to offline or

original drives are re-

 

 

was deleted due to

inserted and the foreign

 

 

missing physical disks.

configuration is imported.

SAS

Controller booted to safe

This issue occurs if

Reseat and cable the

Discovery

mode due to critical

expanders are not

expanders.

 

errors Critical Error

detected.

 

 

during boot - On-board

 

 

 

expander FW or mfg image

 

 

 

is corrupted - reflash

 

 

 

image

 

 

31

Page 31
Image 31
Dell UCPM-800 manual Troubleshooting, Shared Perc 8 Card Boots Into Safe Mode