Combustion Air and Venting

SECTION II - Combustion Air and

Potential contaminating products

Venting

-

Spray cans containing chloro/fluorocar-

Combustion Air Contamination

 

bons

-

Permanent Wave Solutions

 

 

 

 

WARNING

 

 

 

-

Chlorinated wax

 

If the PERFORMANCE PLUS combus-

-

Chlorine - based swimming pool chem-

 

tion air inlet is located in any area likely

 

icals / cleaners

 

to cause or contain contamination, or if

- Calcium Chloride used for thawing ice

 

products, which would contaminate the

 

-

Sodium Chloride used for water soften-

 

air cannot be removed, the combustion

 

air must be repiped and terminated to an

 

ing

 

outside location. Contaminated combus-

-

Refrigerant leaks

 

tion air will damage the unit and its

-

Paint or varnish removers

 

burner system, resulting in possible

 

severe personal injury, death or substan-

-

Hydrochloric acid / muriatic acid

 

tial property damage.

-

Cements and glues

 

 

 

 

 

 

- Antistatic fabric softeners used in

 

WARNING

 

 

clothes dryers

 

 

- Chlorine-type bleaches, detergents, and

 

 

 

 

Do not operate a PERFORMANCE

 

 

cleaning solvents found in household

 

PLUS if its combustion air inlet is taken

 

laundry rooms

 

inside in a laundry room or pool facility.

-

Adhesives used to fasten building prod-

 

These areas will always contain haz-

 

ardous contaminants.

 

ucts and other similar products

 

Pool chemicals, laundry products, com-

Areas likely to contain these products

 

mon household cleaners and hobby

 

products often contain fluorine or chlo-

-

Dry cleaning / laundry areas and estab-

 

rine compounds. When these chemicals

 

lishments

 

pass through the burner and vent sys-

-

Beauty salons

 

tem, they can form strong acids. These

 

acids can create corrosion of the outer

-

Metal fabrication shops

 

tank, burner components and vent sys-

- Swimming pools and health spas

 

tem, causing serious damage and pre-

 

-

Refrigeration Repair shops

 

senting a possible threat of flue gas

 

spillage or water leakage into the sur-

-

Photo processing plants

 

rounding area.

 

-

Auto body shops

 

Please read the information listed below.

 

-

Plastic manufacturing plants

 

If contaminating chemicals are located

 

-

Furniture refinishing areas and estab-

 

near the location of the combustion air

 

inlet, the installer should pipe the com-

 

lishments

 

bustion air inlet to an outside area per

-

New building construction

 

SECTION VI of this installation manual.

-

Remodeling areas

 

 

 

 

 

 

-

Garages with workshops

 

 

 

 

 

 

 

 

 

 

7