Domestic Piping

 

 

SECTION IV - Domestic Piping

 

 

CAUTION

 

 

 

General Piping Requirements

 

 

The Temperature / Pressure relief valve

• All plumbing must meet or exceed all

is not intended for constant duty, such as

local, state and national plumbing codes.

relief of pressure due to normal thermal

• Use pipe dope or tape suitable for

expansion.

 

 

potable water.

Water Hammer

• Use isolation valves to isolate system

 

 

components.

Water hammer is the effect of sudden pres-

• Install unions for easy removal of the

sure changes occurring in the domestic pip-

ing. These pressure changes are typically

PERFORMANCE PLUS from the sys-

the result of “fast acting” positive shut-off

tem piping.

valves closing. These types of valves can

 

Domestic Supply Pressure

be typically found on dishwashers and

clothes washers.

For applications in which the domestic sup-

The effects of water hammering can cause

ply pressure exceeds 70 psig it is recom-

damage to system components and tank

mended to install a pressure reducing valve

welds on the unit.

on the cold water supply.

Installation of hammer arresters is recom-

Maintaining the cold water supply at or

mended at these types of appliances, which

below 70 psig will prevent normal thermal

incorporate “fast-acting” positive shut-off

expansion from repeatedly forcing the T&P

valves. Consult the manufacturer of water

relief valve open.

hammer arresters for recommendation on

 

sizing and installation requirements.

Thermal Expansion

If the cold water supply contains a backflow preventer, check valve and / or a pressure reducing valve, the installer must install a domestic thermal expansion tank on the cold water supply. (See Fig. 6 page 17)

Installing a thermal expansion tank will prevent normal thermal expansion from repeatedly forcing the T&P relief valve open.

When installing a thermal expansion tank ensure the charge pressure of the tank is equal to the cold water supply pressure at the point of installation. Consult the ther- mal expansion tank manufacturer’s instruc- tions for further information on installation and sizing.

Temperature / Pressure Relief Valve

The PERFORMANCE PLUS has a factory installed Temperature / Pressure Relief valve. Ensure the rating of the T&P relief valve is correctly sized as follows per AGA:

 

 

 

 

 

Model

AGA Rating

 

 

PG PLUS-25

100,000 Btu/hr

 

 

PG PLUS-30

200,000 Btu/hr

 

 

PG PLUS-35

200,000 Btu/hr

 

 

PG PLUS-40

200,000 Btu/hr

 

 

PG PLUS-45

200,000 Btu/hr

 

 

 

 

 