Desa SDVBPD, SDVBND Venting Installation, Continued, Horizontal Termination Configurations

Models: SDVBPD SDVBND

1 42
Download 42 pages 10.67 Kb
Page 15
Image 15
Horizontal Termination Configurations

VENTING INSTALLATION

Continued

Horizontal Termination Configurations

Figures 28 through 30 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. Seal all connections with high temperature silicone sealant (outer pipe only) as specified in the second warning statement on page 12. All horizontal piping runs require 1/4" rise per 12" of horizontal run.

Horizontal Venting

Vertical (V) Horizontal (H)

52" min.

26" max.

63" min.

49" max.

86" min.

96" max.

91" min.

20' max.

Figure 28 - Horizontal Termination Configuration for Venting Using One 90° Elbow

VENTING INSTALLATION

15

Installation for Horizontal Termination (Cont.)

 

 

Venting with Three 90° Elbows

Vertical (V)

Horizontal (H1)

Horizontal (H1) +

6' min.

4' max.

Horizontal (H2)

8' max.

7' min.

6' max.

12' max.

8' min.

8' min.

20' max.

20' max.

8' max.

20' max.

Figure 29 - Horizontal Termination Configuration for Venting Using Three 90° Elbows

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

6' min.

4' max.

7' min.

6' max.

8' min.

10' max.

20' max.

12' max.

Figure 30 - Horizontal Termination Configuration for Venting

Using Two 90° Elbows with Termination at 90° with Stove