Pressure Testing Burner System Gas Connections

22

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Checking Gas Connection (Cont.)

Installing Optional Wall Mount Switch - GWMS2

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Continued

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 43 for propane/LP or Figure 44 for natural). Apply noncorrosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Burner System Gas Connections

1.

Open equipment shutoff valve (see Figure 42, page 21).

2.

Open propane/LP supply tank valve for propane/LP burner

 

system or main gas valve located on or near gas meter for natu-

 

ral gas burner system.

3.

Make sure control knob of burner system is in the OFF position.

4.

Check all joints from equipment shutoff valve to thermostat

 

gas valve (see Figure 43 for propane/LP or Figure 44 for natu-

 

ral). Apply noncorrosive leak detection solution to all gas joints.

Gas Valve

Equipment

Shutoff

Valve

Gas Meter

Bubbles forming show a leak. Correct all leaks at once.

5. Light burner system (see Operating Stove with Burner System,

page 26). Check all other internal joints for leaks.

Figure 44 - Checking Gas Joints for Natural Gas Burner System (Oxford™ Model Shown)

6.Turn off burner system (see To Turn Off Gas to Appliance, page 26).

Equipment

 

Shutoff

Propane/LP

Valve

Supply Tank

Gas Valve

 

Figure 43 - Checking Gas Joints for Propane/LP Gas Burner System (Oxford™ Model Shown)

INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 45. If wires are not connected as shown the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

To Control

Switch or

Optional

Accessory

TPTH TP TH

Figure 45 - Control Valve Terminals

INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2Manual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background