OPERATING STOVE WITH BURNER SYSTEM

26

OPERATING STOVE AND BURNER SYSTEM

For Your Safety Read Before Opening

Lighting Instructions

To Turn Off Gas To Appliance

OPERATING STOVE WITH BURNER SYSTEM

FOR YOUR SAFETY

READ BEFORE LIGHTING

FOR YOUR SAFETYWARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Turn ON/OFF switch, located on side of rear cover, to “OFF”.

3.Open lower door panel.

4.Turn off all electric power to the burner system.

5.Push in gas control knob slightly and turn clockwise LIGHTING to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not re- quire accessing for lighting.

8.Turn gas control knob counterclockwise TO TURN OFF GAS to “PILOT”.

9.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service techni- cian or gas supplier.

10.Turn gas control knob counterclockwise Manual background to “ON”.

11.Turn on all electric power to the burner system.

12.Turn the ON/OFF switch to ON position.

13.This valve is equipped with a HI/LO feature. Set burner system input as desired.

14.Close lower panel.

TO TURN OFF GAS

TO APPLIANCE

1.Turn ON/OFF switch, located on side of rear cover, to “OFF”.

2a. Open lower door panel.

2b. If Using Optional Hand-Held Remote: Set selector switch, located on side of rear cover, in the OFF position to pre- vent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise Manual background to “OFF”.

5.Close lower panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise Manual background to the PILOT position.

2.Set selector switch in the OFF position.

Piezo

Gas Control Knob

 

Variable

 

Control Knob

Ignitor

 

 

 

 

 

 

 

 

 

 

OT

 

 

 

 

P

IL

 

 

 

 

 

 

ILO

 

 

 

 

P

T

 

 

 

 

F

O

HI

 

 

 

F

N

 

 

TH

 

O

 

 

 

 

 

 

 

 

 

LO

 

TP

 

 

 

 

 

TPTH

 

IN

OUT

 

 

 

Figure 59 - Control Valve

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

112126-01B

Page 26
Image 26
Desa SDVBND, SDVBPD Operating Stove With Burner System, For Your Safety Read Before Lighting, Lighting Instructions