VENTING INSTALLATION
Continued
Vertical Venting
V = 40' max.
Note: Install restrictor into 4" collar of burner system as shown.
Figure 38 - Vertical Venting Configuration With No Horizontal Run
HIGH ALTITUDE INSTALLATION
Your cast iron stove and
When installing this stove at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification and proper orifice for your location..
When installing this stove at an elevation above 4500 feet (in Canada), check with local authorities.
For assistance with any high altitude installation contact DESA’s Technical Service Department at
VENTING INSTALLATION | 19 |
Installation for Vertical Termination (Cont.) | |
High Altitude Installation |
|
Parts List for Venting Kits and Components |
|
|
|
PARTS LISTS FOR VENTING KITS AND COMPONENTS
Number | Description |
Ground Floor Vent Kit, Black | |
| Includes: Horizontal Square Termination, 90° Elbow, 7"- |
| 12"AdjustableCoaxialPipe,6"PipeAdaptor,12"Coaxial |
| Pipe, Wall Firestop, Decorative Trim Plate and 18 Screws |
Basement Vent Kit | |
| Includes: Horizontal Square Termination, 90° Elbow, 7"- |
| 12" Adjustable Coaxial Pipe, 6" Pipe Adaptor, 4' Coaxial |
| Pipe, Wall Firestop, Decorative Trim Plate and 18 Screws |
Snorkel Vent Kit | |
| Includes: 36" Snorkel Termination, 90° Elbow, |
| Adjustable Coaxial Pipe, 6" Pipe Adaptor, 4' Coaxial |
| Pipe,WallFirestop,DecorativeTrimPlateand18Screws |
Roof Vent Kit | |
| Includes: Vertical High Wind Termination, Flue Restric- |
| tor, |
| Coaxial Pipe, 4' Coaxial Pipe, Firestop Decorative Trim |
| Plate, Roof Flashing, Storm Collar and 18 Screws |
12" Black Coaxial Pipe (1 pk) | |
24" Black Coaxial Pipe (1 pk) | |
48" Black Coaxial Pipe (1 pk) | |
6" Black Coaxial Pipe (1 pk) | |
90° Elbow (1 pk) | |
45° Elbow (1 pk) | |
6" Adaptor Collar, Black (1 pk) | |
Wall Strap (1 pk) | |
Storm Collar (1 pk) | |
Vertical Round Termination (1 pk) | |
Wall Firestop (1 pk) | |
Vertical Restrictor (1 pk) | |
Firestop Plate (1 pk) | |
Horizontal Square Termination (1 pk) | |
Cathedral Ceiling Support Box (1 pk) | |
Roof Flashing 0 to 6/12 Pitch (1 pk) | |
Roof Flashing 6/12 to 12/12 Pitch (1 pk) | |
Vinyl Siding Standoff (1 pk) | |
Trim Plate, Black (1 pk) | |
Horizontal Round Termination (1 pk) | |
14" Snorkel Termination (1 pk) | |
36" Snorkel Termination (1 pk) |