Desa (V) CB36(N Gas Supply And Piping, High Altitude Installation, Check Gas Type, Continued

Models: (V) CB36(N

1 40
Download 40 pages 48.51 Kb
Page 12
Image 12
Installing and Activating the Remote Receiver

11

INSTALLATING OPTIONAL CONTROLS (Cont.)

Installing Optional Wireless Remote Control - Model WRC

HIGH ALTITUDE INSTALLATION

GAS SUPPLY AND PIPING

Check Gas Type

Installing Gas Piping to Fireplace

INSTALLING OPTIONAL CONTROLS

Continued

INSTALLING OPTIONAL WIRELESS REMOTE CONTROL - MODEL WRC (Electronic Ignition)

Installing and Activating the Remote Receiver

1.Open bottom louver and locate the plug receptacle. The plug receptacle is located either on the right or left side of cabinet.

2.The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 20).

3.Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 21). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Replace the bottom louver panel.

When installing a non-high altitude fireplace at an elevation above 2000 feet (610 m) (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet (305 m) above sea level. Check with your local gas company for proper derate procedure and orifice size.

When installing this fireplace in Canada at an elevation above 4500 feet (1372 m), Check with local or provincial code authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

GAS SUPPLY AND PIPING

CHECK GAS TYPE

Fireplace Receptacle

Remote Control Receiver

Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gastypeortopurchasegasconversionkit(seeAccessories,page33).

INSTALLING GAS PIPING TO FIREPLACE

Extension Cord

Ignition

Module Plug

Figure 20 - Connecting WRC Remote Control Electronic

Battery Cover

12 Volt Battery

Back of

Pull to Remove

Handset
Insulation Tab

Figure 21 - Installing Battery into Back of Handset

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved in the USA for elevations from 0-2000 feet (610 m) and in Canada at elevations from 0-4500 feet (1372 m).

GAS SUPPLY AND PIPING WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

CHECK GAS TYPE CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

External

Propane/LP

Regulator
Supply Tank
Vent

Pointing

Down

Figure 22 - External Regulator with Vent Pointing Down (Pro- pane/LP Only)