TROUBLESHOOTING
Manual Ignition System (Cont.) | 22 |
TROUBLESHOOTING
Manual Ignition System (Continued)
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Burner does not light after pilot is lit | 1. | Burner orifice clogged | 1. | Clean burner (see Cleaning and Mainte- |
or cycles during operation. |
|
|
| nance, page 20) or replace burner orifice |
| 2. | Inlet gas pressure is too low | 2. | Contact local propane/LP or natural gas |
|
|
|
| company |
| 3. | Thermopile leads disconnected or im- | 3. | Reconnect leads |
|
| properly connected |
|
|
| 4. | Thermopile is defective | 4. | Replace thermopile |
| 5. | Improper venting or excessive blockage | 5. | Have the vent system inspected, includ- |
|
|
|
| ing the termination cap. Remove any |
|
|
|
| restriction or obstruction |
|
|
|
|
|
Delayed ignition at burner | 1. | Manifold pressure too low | 1. | Contact local propane/LP or natural gas |
|
|
|
| company |
| 2. | Burner porting or orifice clogged | 2. | Clean burner (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
|
|
|
|
|
Burner backfiring during combustion | 1. | Burner orifice is clogged or damaged | 1. | Clean burner (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
| 2. | Damaged burner | 2. | Replace damaged burner |
| 3. | Gas regulator defective | 3. | Replace gas control |
Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing
1.Problem will stop after a few hours of operation
Heat produces a wistling noise when | 1. | Turning gas control knob to HI position | 1. | Turn gas control knob to LO position and |
burner is lit |
| when burner is cold |
| let warm up for a minute |
| 2. | Air in gas line | 2. | Operate burner until air is removed from |
|
|
|
| line. Have gas line checked by pro- |
|
|
|
| pane/LP or natural gas company |
| 3. | Dirty or partially clogged burner orifice | 3. | Clean burner (see Cleaning and Mainte- |
|
|
|
| nance, page 20) or replace burner orifice |
|
|
|
|
|
Glass soots | 1. | Flame impingement on logs | 1. | Adjust the log set so the flame does |
|
|
|
| equipment shutoff valve |
| 2. | Debris around burner air mixer | 2. | Inspect the opening at the base of the |
|
|
|
| burner to see that it is not packed with |
|
|
|
| any type of material |
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
1.Metal expanding while heating or con- tracting while cooling
1.This is common. If noise is excessive, contact qualified service person
Remote does not function | 1. Batteryisnotinstalledorbatteryispower | 1. Replace |
| is low | remote control |
www.desatech.com |