OPERATING FIREPLACE - Manual Ignition System
For Your Safety Read Before Lighting | 16 |
Lighting Instructions
To Turn Off Gas To Appliance
Manual Lighting Procedure
OPERATING FIREPLACE
Manual Ignition System
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty, damage, personal injury or loss of life.
•If gas control knob does not pop up when released, stop and immediately call your service technician or gas suppier.
•If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service techni- cian or gas supplier.
9.Turn on all electric power to fireplace.
10.Turn gas control knob counterclockwise to “ON”.
11.Close lower louver panel.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floorbecause some gas is heavier than air and will settle on the floor.
Gas Control | Regulator Cap |
| |
Knob |
|
ILOT | O |
P | |
F | N |
F |
|
O |
|
Piezo Ignitor
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s Phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1.STOP! Read the safety information above.
2.Open lower louver panel.
3.Turn off all electric power to the fireplace.
4.Push in gas control knob slightly and turn clockwise to “OFF” (see Figure 33).
5.Wait five (5) minutes to clear out any gas. Then smell for. gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas go to the next step.
6.The pilot is located by the main burner and should not re- quire accessing for lighting.
7.Turn gas control knob counterclockwise to “PILOT”.
8.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
Figure 33 - Control Valve Millivolt
TO TURN OFF GAS
TO APPLIANCE
1.Open lower louver panel.
2.Set the wall switch to the OFFposition orthe GHRC selector switch (when equipped) to prevent draining the battery.
3.Turn off all electric power to the appliance if service is to be performed.
4.Push in gas control knob slightly and turn clockwise to “OFF”.
5.Close lower louver panel.
Shutting Off Berners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
1.Turn gas control knob clockwise to the PILOT position.
2.Set the wall switch to the OFF position or the HRC selector switch (when equipped) to prevent draining the battery.
MANUAL LIGHTING
PROCEDURE
1.Remove glass door (see Removing/Replaceing Glass Door, page 14).
2.Follow steps 1 through 8 under Lighting Instructions.
3.Depress gas control knob and light pilot with match.
4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 11 under Lighting Instructions.
5.Replace glass door (see Removing/Replacing Glass Door, page 14).
www.desatech.com |