PRE-INSTALLATION PREPARATION

5Clearances

Framing and Finishing

PRE-INSTALATION PREPARATION

Continued

PACKAGING AND REMOVAL

The (V)CB36 vented decorative gas fireplaces are packaged with:

-one box containg a 4-log set located on the burner in the firebox.

-one bag containing the owner’s manual with installation

instructions, operator’s guide, and warranty information.

-one bag of glowing ember material.

-one bag of vermiculite hearth treatments.

Remove the shrinkwrap securing the 2 carton trays to the unit.

Lift the top carton tray off and remove the four corner posts.

Discard the bottom tray once the unit is moved into position.

Note: To prvent damage to ceramic logs and glass panels you may want to remove them before positioning and framing the unit. To access firebox, see Hearth Access and Assembly, page ##.

CLEARANCES

Minimumclearancestocombustiblesforthefireplaceareasfollows:

Back, and sides

0” (0 mm)

Perpendicular walls

10” (254 mm)

Floor

0” (0 mm)

Ceiling to louver opening

36” (914 mm)

Front

36” (914 mm)

Top

0” (0 mm)

B-Vent Surfaces

1” (26 mm) (See venting instructions

 

for specifics on vent clearances.)

Mantel Clearances

(See - Mantel Clearances for specific

 

clearances to combustible mantels.)

Carton Tray

Glass Panel

Corner Post

Log Carton

Figure 4 - Unpacking Fireplace

2 x 4 FLAT HEADER

36"

(914 mm)

36 1/4" (921 mm)

14 3/4" (375 mm)

Figure 5 - Framing Clearances for Flush, Wall Installation

Combustible material with a maximum thickness of 5/8” (16 mm) may be flush with the top and sides of the front face of the fireplace.

FRAMING AND FINISHING

Figure 5 shows typical framing of this fireplace. Figure 6 shows framing for corner installation. All minimum clearances must be met.

For overall unit dimensions, framing allowances, and vent collar locations, see Unit Dimensions, Figure 7 on page 6.

For available accessories for this fireplace, see Accessories on page

33.If you are using a seperate combustible mantel piece, refer to Figures 8 and 9 for proper height and clearances. You can install a noncombustible mantel at any height above the fireplace opening. Note: Non-combustible mantels may discolor!

21" (533 mm)

TO CENTER OF

TOP VENT

285/8"

(727 mm)

14 3/4"

563/4"

(1441 mm)

THESE DIMENSIONS ALLOW FOR 1" OF CLEARANCE

AT THE SIDES AND BACK OF THE FIREPLACE

HOWEVER, 0" CLEARANCE IS ALSO PERMITTED AT ALL SIDES WHEN FRAMED

14 3/4"

(375 mm)

TO NAILING FLANGES

121/4"

(311 mm)

TO

OPENING

Figure 6 - Framing Clearances for Corner Installation

www.desatech.com

117437-01

Page 6
Image 6
Desa (V) CB36(N installation manual PRE-INSTALATION Preparation, Clearances, Framing and Finishing