INSTALLATION PRECAUTIONS

INSTALLATION PRECAUTIONS

7VENTING INSTALLATION

INSTALLATION PRECAUTIONS

VENTING INSTALLATION

NOTICE: Failure to follow these instructions will void the warranty.

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on this product:

Installation of any damaged venting component

Unautorized modification of the venting system (Do not cut or alter vent components)

Installation of any component part not manufactured or ap- proved by DESA.

Installation other than as instructed by these instructions

VENTING INSTALLATION WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE: Failure to follow these instructions will void the warranty. WARNING: B-type vent pipe airspace clearance to combustibles is 1” on all sides. Where the vent pipe passes through a vertical wall a listed thimble approved for use with B-type vent must be used.

A 4" B-type venting system must be connected to the appliance for venting to the outside of the building.

The following section is provided as a guide to install a standad B-type vent installation.

Standing codes requirements concerning B-type vent installations may vary within your state, province or local codes juristdition. Therefore, it is recommended that you check with your local building code authority for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code NFPA No. 54/ANSI Z223.1 or in Canada with CAN/CSA B149 for Category I systems using double wall B-1 vent pipe.

This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance.

This appliance may be vented through a manufactured chimney liner system if all are listed, inspected and approved by local codes and/or building authorities.

The examples shown in Figure 10 are typical of most B-vent installations and code practices.

Manual background WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serv- ing a separate solid fuel burning apppliance.

 

Listed

 

 

 

 

 

 

Vent Cap

 

 

Listed

 

Listed

 

 

 

 

 

 

 

 

 

Vent Cap

 

Vent Cap

 

 

Maintain

 

 

 

 

 

Maintain

Listed

 

 

 

Maintain

 

Listed

Clearance

 

 

 

 

 

Maintain

 

Listed

 

Clearance

 

 

 

 

Support Each

 

Listed

 

Clearance

 

 

 

 

 

 

Lateral At

 

Clearance

 

 

 

 

Least Every

 

 

 

 

 

 

Six (6) Feet

45°

 

 

 

 

60°

 

 

 

 

 

 

 

12' Min.

 

 

 

 

 

 

 

 

 

8'

 

 

 

45°

10'

 

 

 

 

 

 

6'

 

 

 

 

 

12' Min.

Position

Position

45°

Position

 

12' Min.

 

 

Firestop

 

 

 

Firestop

Firestop

 

 

 

 

 

 

 

 

 

Maintain

 

Maintain

 

 

Maintain

 

Listed

 

Listed

 

 

Listed

 

Clearance

 

Clearance

 

 

Clearance

EXAMPLE 1

EXAMPLE 2

EXAMPLE 3

Figure 10 - Typical B-Vent Configuration

www.desatech.com

117437-01

Page 8
Image 8
Desa (V) CB36(N installation manual Installation Precautions, Venting Installation