OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1.

No gas supply, or shutoff valve is OFF

1.

Check to see if you have gas supply and

 

 

 

 

that equipment shutoff valve is opened

 

2.

Air in gas line

2.

Repeat lighting procedure several times

 

 

 

 

to purge all air out of lines. If after re-

 

 

 

 

peated attempts appliance does not light,

 

 

 

 

call for qualified service and repair.

 

3.

Construction debris clogging pilot orifice

3.

Remove debris and dirt, and inspect and

 

 

 

 

clean any other possible obstructions

 

4.

Low gas pressure

4.

Contact your gas supplier to check

 

 

 

 

pressure

 

5.

Kinked pilot line

5.

Have a qualified technician replace pi-

 

 

 

 

lot line

 

6.

Control valve is not opening

6.

Replace control valve (Refer to Replace-

 

 

 

 

ment Parts, page 26)

 

7.

No power to unit or the ignition module

7.

Check that main power is on and that

 

 

 

 

wire connections are made correctly to

 

 

 

 

the ignition model (see Wiring Diagram,

 

 

 

 

page 20). Check for 24 VAC at the sec-

 

 

 

 

ondary side of the transformer. If 24

 

 

 

 

VAC is present, and the module does not

 

 

 

 

operate, have the module replaced oth-

 

 

 

 

erwise have the transformer replaced.

 

 

 

 

 

Pilot will not stay lit

1.

Loose wiring on ignitor wire to ignition

1.

Check wiring connection. Refer to wir-

 

 

module and/or poor ground to ignition

 

ing diagram (see Wiring Diagram, page

 

 

module

 

9) and/or check ground wire to igni tion

 

 

 

 

module

 

2.

Pilot flame too low to sense

2.

Clean and adjust pilot burner and check

 

 

 

 

gas supply and inlet pressure to unit

 

 

 

Note: Have a qualified technician replace

 

 

 

pilot assembly if broken or corroded

 

 

 

 

 

Frequent outage of main burner and pilot

1.

Pilot flame may be too low to sense flame

1.

Cleanandadjustpilotflameformaximum

after complete ignition sequence.

 

causing ignition module to shut down

 

flame across sensor rod.

 

2.

Improper or restricted venting.

2.

Locate and correct all vent conditions

 

 

 

 

(seeCheckingforProperVenting,page8)