Appendix A

This appendix details an example of how to over commit the number of VMkernel ports to the physical NICs. This is usually done in environments in which the NIC is capable of handling multiple sessions such as 10GbE. This can also be done in larger environments combined with a PowerVault SAN to help achieve maximum bandwidth to the SAN.

In this appendix example we are using 2 physical NICs and assigning 3 VMkernel ports to each one for a total of 6 sessions to the SAN.

Step A1: Configure vSwitch and Enable Jumbo Frames

Follow the Step 1 configuration steps in the main document as there are no changes for adding multiple VMkernel ports.

Step A2: Add iSCSI VMkernel Ports

The following command will add a new iSCSI VMkernel Port named iSCSI1 on the vSwitch created in the previous step.

esxcfg-vswitch –A iSCSI1 vSwitch2

This next command will configure the IP Address, Subnet Mask and enable Jumbo Frame support for the new VMkernel Port iSCSI1

esxcfg-vmknic –a –i 10.10.5.173 –n 255.255.255.0 –m 9000 iSCSI1

Following the example from before we are just adding more VMkernel ports. We need to create 5 more VMkernel Ports named iSCSI2, iSCSI3, iSCSI4, iSCSI5 and iSCSI6. Then configure the IP addresses, subnet masks and enable Jumbo Frames.

esxcfg-vswitch –A iSCSI2 vSwitch2

esxcfg-vmknic –a –i 10.10.5.174 –n 255.255.255.0 –m 9000 iSCSI2

esxcfg-vswitch –A iSCSI3 vSwitch2