not use UltraVision, push the Dimension One Spas icon (logo) pad to
reset the system.
NOTE: If you purchased an UltraVision cartridge subsequent to the ini-
tial start up of your spa, please do a 'hard reset' of the system as outlined
on the preceding page to reset the six month time frame. Please be aware
that a hard reset will also reset your clock, filtration cycles, etc. to the
factory defaults.
SPACHECK-UP
When "SPACHECK UP" is displayed on the LCD, the spa has been in
service for 2 years. We recommend that you have your spa inspected by
your dealer as a preventative maintenance measure. Push the Dimension
One spas icon to reset the system.
NOTE: To eliminate any prompting message on the LCD the system can
be reset by pushing the Dimension One Spas icon on the right end of the
control. If the error still exists the message will redisplay.
DIAGNOSTIC MESSAGES
OVERHEAT
When “OVERHEAT” along with the water temperature of the spa, is dis-
played on the LCD, the spa is in a high limit condition. In such a condi-
tion, DO NOT ENTER THE WATER. If this happens, remove the spa
cover and allow the water to cool below 106˚ F, then push any pad on the
upper control and the system will reset. If the problem recurs, turn off all
power to the spa and contact your local Authorized Dimension One Spas
dealer, or authorized service center.
LOW FLOW
When “LOW FLOW” is displayed on the LCD, check the following:
1) Check the water level to see if it is too low. If the water level is too
low, fill the spa to one to two inches above the bottom of the tile line.
2) Check the Ultra Pure filter cartridge to make sure that it is clean and
not impeding the flow of water. If the filter is dirty, clean it and rein-
stall.
3) A flow switch has malfunctioned. The spa will operate but the heater