DKS Enterprises 1808, 1803, 1802, 1810 owner manual Speaker Volume, Feedback, Click Sensitivity

Models: 1803 1810 1808 1802

1 55
Download 55 pages 33.92 Kb
Page 41
Image 41

SECTION 4 – ADJUSTMENTS

4.1Speaker Volume

1.Open the front of the telephone entry system and locate the speaker volume adjustment.

2.Place a phone call from the telephone entry system to a resident. While they are talking, adjust the speaker volume potentiometer for adequate sound. To increase the volume rotate the potentiometer clockwise, to decrease the volume rotate the potentiometer counter clockwise.

4.2Feedback

1.Open the front of the telephone entry system and locate the feedback adjustment.

2.Place a phone call from the telephone entry system to a resident. After they answer, ask the resident to remain silent.

3.While rubbing your finger across the microphone hole, rotate the feedback potentiometer clockwise, and then counter clockwise. When the noise from the speaker is minimum, this is the correct adjustment for the feedback potentiometer.

4.3Click Sensitivity

1.Open the front of the telephone entry system and locate the click sensitivity adjustment.

2.Place a phone call from the telephone entry system to a resident with a rotary dial type phone. After they answer, ask the resident to dial 9 while you adjust the click sensitivity potentiometer (the resident may have to dial 9 several times for you to obtain the correct adjustment). When the door or gate opens, this is the correct adjustment for the click sensitivity.

3.NOTE: Adjusting the click sensitivity too high (potentiometer fully clockwise) could cause the system to respond to loud noises while it is in use. If this happens, rotate the click sensitivity potentiometer counter clockwise 1/8 turn and re-test the system. You may have to perform this step several times to find the correct adjustment.

4.4Display Contrast (1802, 1803, 1810 only)

1.Open the front of the telephone entry system and locate the contrast adjustment.

2.Turn the master code switch on. The display will read MST CODE. While the display is lighted, turn the contrast potentiometer clockwise and then counter clockwise until the display is satisfactory.

3.Turn the master code switch off.

4.NOTE: Approximately 30 seconds after the master code switch is turned on, the system will signal a long tone. This is normal and can be ignored. After the master code switch is turned off, the display will read MST CODE for approximately 30 seconds.