2.2 WIRING DESCRIPTION

The wiring diagram below shows a typical wiring scheme for the telephone entry system.

Terminal 3 is a case ground and not a low voltage common. Using terminal 3 as a low voltage common will cause noise on the phone line.

Switch input 1 (terminals 4 and 8) is pre-wired to the postal switch and pre-programmed to activate relay 1 when the input is closed.

Switch input 2 can be programmed to activate relay 2 or dial a preprogrammed phone number when the input is closed.

Normally Open Switch 2 Input

1

2

3

4

5

6

7

8

9

1 0

1 1

1 2

1 3

1 4

Central Office

Phone Line

Earth Ground

Only

 

 

+

16 VAC, 20 VA

 

 

Normally Open

12 Volt

Transformer

Switch 1 Input

Battery

 

24