Operator’s Guide

Keypad Options

KPD KPD

OPT DIAG STOP

CURRENT KEYPAD ADDRESS: 01

KEYPAD MODE:

*SUP UNSUP

DEFAULT KEYPAD MSG:

Arm panic keys:

PN em F1

Keypad Options (KPD OPT)

To program keypad options, press the left Select key under KPD OPT. The display changes to CURRENT KEYPAD ADDRESS: # #.

Current Keypad Address

The Membrane Keypad must be set to keypad address 01. This is the default setting and should not be changed.

Keypad Mode

The Membrane Keypad can be set for either Supervised or Unsupervised operation. It is recommended the setting be left at the default Supervised setting.

Default Keypad Message

Press COMMAND to scroll past this option. The SCS-1R LCD Membrane Keypad does not provide a programmable Keypad Message.

Arm Panic Keys

The Panic Keys should be disabled. They cannot be used on the SCS-1R LCD Membrane Keypad. If an asterisk appears next to one of the options, for example *PN, press the Select key under the option with the asterisk to remove the asterisk and disable the panic key.

Activate zone 2

Shunt: no yes

Activate zone 3

Exit: no yes

4 digit entry

Cards: no yes

All?: No yes

Delay: 2

Zone 2 Shunt

Leave this option set to NO.

Zone 3 Exit

Leave this option set to NO.

Entry Cards

Leave this option set to NO.

All?

Leave this option set to NO.

Accessing Keypad Diagnostics

KPD

KPD

Keypad Diagnostics (KPD DIAG)

OPT

DIAG STOP

The Keypad Diagnostic option allows you to check the display segments, check the

 

 

keyboard backlighting, and test individual keys.

 

 

 

 

Press the Select key under KPD DIAG. The keypad lights all display segments and

 

 

illuminates the keyboard in green. A few seconds later the keypad turns the display off

 

 

and illuminates the keyboard in red. The keypad then alternates between these two

 

 

states for approximately two minutes. Press COMMAND at any time to continue.

 

Test Individual Keys

Press key to

Test

 

The display changes to PRESS KEY TO TEST. This option allows you to test each key on

 

 

the keyboard to ensure it is operating properly. Press and hold each key for about two

 

 

 

 

seconds. The key number being held appears in the display. Verify the correct number

 

 

displays before testing the next key.

Exiting the Installer Options

When done, press the COMMAND key once to return to the Installer Options screen. Press the Select key under STOP to exit the Installer Options function.

Digital Monitoring Products

SCS-1R Installation Guide

18