Printout Explanations

Printout Explanations

General Description

Note: UL central station applications must use a serial printer listed for Fire Protective Signaling Systems.

The SCS-1R prints out two general types of messages: changes in the system information and messages received from DMP Command Processor panels. The message line for system changes is bracketed by double asterisks with the time of occurrence printed at the far right. Messages from panels always list the account number first followed by the message and the time of occurrence. The printout below is a typical page from an Activity Log.

 

 

 

 

 

ATLAS SECURITY SERVICE, INCORPORATED

 

 

Wednesday

 

5/1/03

 

 

* *

ACTIVITY LOG * *

Page number:

2

* * SECURITY CONTROL SYSTEM NUMBER CHANGED TO: 1.

 

* * 8:01 a.m.

 

* *

LINE:

3 CONFIGURED AS:

DD

PHONE NUMBER:

(214) 555-1212

* * 8:02 a.m.

 

* * DIALER PANEL NUMBER:

108 ADDED TO LINE: 1

 

* * 8:04 a.m.

 

1-

1

Zone:

8

FRONT DOOR

-

BURG

ALARM

8:18 a.m.

 

1-

1

Zone:

2

BACK DOOR

-

BURG

TROUBLE

8:23 a.m.

 

1-

1

Zone:

2

BACK DOOR

-

BURG

RESTORE

8:24 a.m.

 

1-

1

* * AMBUSH *

*

 

 

 

 

8:27 a.m.

 

1-

1

Area:

1

OFFICE

-

DISARMED

Usr: 007

8:31 a.m.

 

 

 

 

2

PLANT

 

 

 

 

 

 

 

 

3

SHIPPING

 

 

 

 

 

1-

1

Zone:

010

FRONT DOOR

-

BYP

Usr: 015

8:33 a.m.

1-

1

Usr: 009 added to panel

 

 

 

Usr: 002

8:33 a.m.

1-

1

Permanent schedule for Tuesday

Area: 1

 

 

8:35 a.m.

 

 

Open:

8:00

a.m.

Close:

5:30 p.m.

Usr: 005

 

1-

1

Door access

Dr: 001

 

Usr: 021

 

8:36 a.m.

1-

1

WARNING: Low standby battery

 

 

8:38 a.m.

1-

1

Zone:

37

SMOKE DET.

 

-

FIRE

ALARM

8:40 a.m.

System Messages

System messages are provided on the Activity Log printer to provide a permanent record of changes made to the system information. The operator making the change is determined by referring to the last sign on.

Command Processor Messages

Messages from Command Processor panels are sent to the SCS-1R advising of various changes in the panel status. The messages print and/or display on the LCD.

Alarm, Trouble, and Restore

These messages are all formatted the same. Alarm and Trouble messages print to the Activity Log and display on the LCD for acknowledgment.

Fire and Supervisory restorals display on the LCD for acknowledgment and printed to the Activity Log while other restore messages print to the Activity Log only.

Ambush

The Ambush message prints and displays on the LCD for acknowledgment.

Opening and Closing

Openings and Closings reports list the areas that are armed or disarmed and the user name making the change. These messages can be from 1 to 8 consecutive lines and print to the Activity Log only.

Bypass and Reset

This message prints in a one line format listing the zone number, zone name, and user name making the change. The message prints on the Activity Log only.

Schedule Changes

This prints in a 2-line format listing the type of schedule, day of the week, opening and closing time, and the user name making the change. This message prints on the Activity Log only.

Digital Monitoring Products

SCS-1R Installation Guide