7.3.5Menu level 4: Space factor

_IA_CA1000.book Seite 33 Freitag, 30. Januar 2009 11:12 11

Dometic CA1000

Installation

7.3.5Menu level 4: Space factor

The space factor (03 to 20) affects the power levels of the compressor and fan in automatic mode. If the space to be cooled is very large, select a higher space factor:

Start configuration mode (see chapter “Start and end configuration mode” on page 31).

The first digit of the display (fig. e 5, page 6) shows the menu level and the second and third show the parameter which can be set.

Press the + button (fig. e 6, page 6) three times to switch to menu level 4.

Press the Mode button (fig. e 4, page 6) to change the parameter.

The digits in the display flash until the parameter you enter is con- firmed.

Use the + and buttons (fig. e 6 and 7, page 6) to select the temper- ature (in °C) with which the system starts.

Press the Mode button (fig. e 4, page 6) to confirm your entry.

The set value is saved and is then used when the system is restarted.

You are now in menu level 4 and can use the + and buttons to switch between menu levels.

7.3.6Menu level 5: Default setting

You can return the parameters you set in configuration mode on menu levels 1 to 4 to the default settings:

Start configuration mode (see chapter “Start and end configuration mode” on page 31).

The first digit of the display (fig. e 5, page 6) shows the menu level and the second and third show the parameter which can be set.

Press the + button (fig. e 6, page 6) four times to switch to menu level 5.

The digital display shows 00.

Press the Mode button (fig. e 4, page 6) to return the system to its default settings.

The digits in the display 00 flash. Press the + button.

The digital display shows 01.

Press the Mode button (fig. e 4, page 6) to confirm your entry.

The parameters set in configuration mode are returned to the default setting.

You are now in menu level 5 and can use the + and buttons to switch between menu levels.