Dukane 8919H-RJ, 8920H-RJ Cleaning and replacing the air filter, Type number MU06481 Filter set

Models: 8755J-RJ 8919H-RJ 8920H-RJ

1 75
Download 75 pages 19.48 Kb
Page 64
Image 64
Cleaning and replacing the air filter

Maintenance

Cleaning and replacing the air filter

The air filter unit of this projector consists of a filter cover, two kinds of filters, and a filter frame. The new double large filters system is expected to function longer. However, please check and clean it periodically to keep ventilation needed for normal operation of the projector.

When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. Replace the filters when they are damaged or too soiled. To prepare new filters, make contact with your dealer and tell the following type number.

Type number : MU06481 (Filter set)

When you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector.

1. Turn the projector off, and unplug the power cord. Allow the projector to sufficiently cool down.

2. Use a vacuum cleaner on and around the filter cover.

3. While supporting the projector with one hand, use your other hand to pull the filter cover forward in the direction of the arrow.

4. Use a vacuum cleaner for the filter vent of the projector and the outer side of the filter unit.

5. Take the filters out while holding the filter cover.

6. Use a vacuum cleaner on both sides of the filters. When vacuuming up the fine meshed filter, hold it so it will not be sucked in. If the filters are damaged or heavily soiled, replace them with the new ones.

7. Put the filters back into the filter cover.

Put the coarse meshed filter into a filter cover first. Then put the fine meshed filter on the coarse meshed one, turning its stitched side up.

8. Put the filter unit back into the projector.

Filter cover

2

 

3

Filter unit

4

Filter cover

7

Filter (coarse meshed) Filter (fine meshed)

Type number : MU06481 (Filter set) Stitched Manual background side

(continued on next page)

64

Page 64
Image 64
Dukane 8919H-RJ, 8920H-RJ, 8755J-RJ user manual Cleaning and replacing the air filter, Type number MU06481 Filter set