Dynacord DPA 4140 owner manual Specifications, 12.1DPA 4120 power amplifier 200 W power supply

Models: DPA 4120 DPA 4140

1 72
Download 72 pages 6.17 Kb
Page 42
Image 42

12.Specifications

12.1DPA 4120 power amplifier 200 W power supply:

mains operation

 

 

 

 

 

115 V / 230 V~ AC, ±10 %

 

 

mains frequency

 

 

 

 

 

50 - 60 Hz

 

 

 

 

 

security class

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mains operation

Umains / V

Imains / A

 

Pmains / VA

Pmains / W

 

Pout / W

 

Pv / W

idling

230

0.13

 

30

 

16

 

0

 

16

normal operation (-10 dB)

230

0.83

 

191

 

138

 

20

 

118

alarm (-3 dB)

230

1.67

 

384

 

298

 

100

 

198

standard conditions

230

2.27

 

522

 

415

 

200

 

215

initial current inrush (mains)

 

 

< 29 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mains operation

Umains / V

Imains / A

 

Pmains / VA

 

Pmains / W

 

Pout / W

 

Pv / W

idling

115

0.26

 

30

 

16

 

0

 

16

normal operation (-10 dB)

115

1.67

 

191

 

138

 

20

 

118

alarm (-3 dB)

115

3.34

 

384

 

298

 

100

 

198

standard conditions

115

4.54

 

522

 

415

 

200

 

215

initial current inrush (mains)

 

 

< 20 A

 

 

 

 

 

 

 

 

 

 

 

Pmains / VA = apparent power Umains*

Imains; Pmains / W = true power; Pout / W = output power; Pv / W =leakage power

battery operation

 

 

 

 

 

24 V DC, -10/+30 %

 

 

 

 

 

 

 

 

 

 

 

 

battery operation

UB / V

 

IB / A

 

Pi / W

 

Pout / W

 

Pv / W

stand-by

24

 

2.5m

 

60m

 

 

0

 

 

60m

idling

24

 

0.43

 

10

 

 

0

 

10

normal operation (-10 dB)

24

 

3.74

 

90

 

 

20

 

90

standard conditions

24

 

9.10

 

218

 

131

 

87

initial current inrush (battery)

 

 

< 3.8 A

 

 

 

 

 

 

 

 

Pi / W = input power UB*IB; Pout / W =

output power;

Pv / W = leakage power

 

 

 

 

 

 

 

features of the input: nominal input level

nominal input impedance features of the power output:

nominal output capacity during mains operation nominal load impedance

frequency response

distortion at 1 kHz and nominal output power interfering voltage (A)

features of the monitor output: nominal output voltage nominal load impedance

ambient temperature range dimensions (W x H x D) depth with / without connections weight without extensions finish

electronically balanced 775 mV = 0 dBu

t10 k ohms balanced, floating

200 W (according to IEC 268-3)

50 ohms / 100V; 25 ohms / 70 V; 12.5 ohms / 50 V or 4 ohms / 28 V

60 Hz .. 20 kHz d 1 %

d 1.2 mV = -56 dBu electronically balanced 2 V = + 8.2 dBu

600 ohms

+5 °C .. +40 °C

483 x 132 x 345 mm

max. 400 mm / max. 340 mm

13.2kg

anthracite

42

Page 42
Image 42
Dynacord DPA 4140 Specifications, 12.1DPA 4120 power amplifier 200 W power supply, mains operation, battery operation