8.Enhanced application field

8.Enhanced application field

8.1Standard input module NRS 90225

This input module for the power amplifiers DPA 4120 and DPA 4140 is meant for insertion at the power amplifiers' rear. It provides the following functions:

lockable XLR input connector

XLR output connector; to patch the input signal through

gain control; to be adjusted using a screwdriver

mains remote ON/OFF

battery remote ON/OFF

control of the D- and E-relays

fault messages via the READY relay contact:

-thermal overload of the mains transformer

-thermal overload of the power amplification stage

-ground fault (optional; only with installed NRS 90224)

-pilot tone signal (optional; only with installed NRS 90224)

MONITOR output; electronically balanced

input transformer for floating, balanced input; optional

output transformer for floating, balanced monitor output; optional

The input module is meant to be used with the power amplifiers DPA 4120 and DPA 4140. The module allows to control and monitor the operation of the power amplifiers using conventional equipment or (with reservations) by the PROMATRIX manager DPM 4000.

Caution: Before installing the input module NRS 90225, you have to unplug the mains connector as well as a presumably connected battery cord.

Before installing the input module, it is necessary to remove the two locking screws B on the rear panel of the appliance. For installation the printed board assembly first has to be inserted into the guiding rails. After carefully pushing the module in it has to be locked by using the two screws mentioned before.

Note: Functioning changes in the models DPA 4120 (starting with serial numbers: 100 11) and DPA 4140 (starting with serial numbers: 100 11) in association with the input module NRS 90225: To achieve reliable attenuation of switching noise (knacks), the monitor output stays muted as long as the READY-relay is not pulled. Because of circuit design reasons this causes that the monitor output is also muted even when a ground-fault appears at the main output.

8.2Remote module NRS 90222

This input and remote module for the power amplifiers DPA 4120 and DPA 4140 is meant for insertion at the power amplifiers' rear. It provides the following functions:

lockable XLR input connector

XLR output connector; to patch the input signal through

input level; can be set via a programmable audio level control

MUTE (via level control)

mains remote ON/OFF

battery remote ON/OFF

control of the D- and E-relays

surveillance and fault messaging via the PROMATRIX manager DPM 4000 corresponding to IEC 849

-thermal overload of the mains transformer

-thermal overload of the power amplification stage

-ground fault (optional; only with installed NRS 90224)

-pilot tone signal (optional; only with installed NRS 90224)

-measurement of the output voltage / level

-measurement of the output current

-surveillance of the connected loads via current/voltage measurement

MONITOR output; electronically balanced

monitoring: input/output signals can be assigned to the monitor bus

input transformer for floating, balanced input (optional)

output transformer for floating, balanced monitor output (optional)

pilot tone signal ON/OFF (optional)