Dynacord DPA 4120 owner manual 12.2DPA 4140 power amplifier 400 W power supply, mains operation

Models: DPA 4120 DPA 4140

1 72
Download 72 pages 6.17 Kb
Page 43
Image 43

12.2DPA 4140 power amplifier 400 W power supply:

mains operation

 

 

 

 

 

115 V / 230 V~ AC, r10 %

 

 

mains frequency

 

 

 

 

 

50 - 60 Hz

 

 

 

 

 

 

security class

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mains operation

Umains / V

Imains / A

 

Pmains / VA

 

Pmains / W

 

Pout / W

 

Pv / W

idling

230

0.19

 

44

 

23

 

 

0

 

23

normal operation (-10 dB)

230

1.60

 

368

 

263

 

 

40

 

223

alarm (-3 dB)

230

3.10

 

713

 

562

 

 

200

 

362

standard conditions

230

4.43

 

1019

 

811

 

 

400

 

411

initial current inrush (mains)

 

 

< 36 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mains operation

Umains / V

Imains / A

 

Pmains / VA

 

Pmains / W

 

Pout / W

 

Pv / W

idling

115

0.38

 

44

 

23

 

 

0

 

23

normal operation (-10 dB)

115

3.19

 

368

 

263

 

 

40

 

223

alarm (-3 dB)

115

6.20

 

713

 

562

 

 

200

 

362

standard conditions

115

8.86

 

1019

 

811

 

 

400

 

411

initial current inrush (mains)

 

 

< 21 A

 

 

 

 

 

 

 

 

 

 

 

 

Pmains / VA = apparent power Umains*

Imains; Pmains / W = true power; Pout / W = output power; Pv / W =leakage power

battery operation

 

 

 

 

 

24 V DC, -10/+30 %

 

 

 

 

 

 

 

 

 

 

 

 

battery operation

UB / V

 

IB / A

 

Pi / W

 

Pout / W

 

Pv / W

stand-by

24

 

2.5m

 

60m

 

 

 

0

 

60m

idling

24

 

0.62

 

 

15

 

 

 

0

 

15

normal operation (-10 dB)

24

 

7.1

 

 

170

 

 

 

40

 

130

standard conditions

24

 

17.3

 

 

415

 

 

249

 

166

initial current inrush (battery)

 

 

< 3.8 A

 

 

 

 

 

 

 

 

 

 

 

Pi / W = input power UB*IB; Pout / W =

output power;

Pv / W = leakage power

 

 

 

 

 

 

 

 

features of the input: nominal input level nominal input impedance features of the power output:

nominal output capacity during mains operation nominal load impedance

frequency response

distortion at 1 kHz and nominal output power interfering voltage (A)

features of the monitor output: nominal output voltage nominal load impedance

ambient temperature range dimensions (W x H x D) depth with / without connections weight without extensions finish

electronically balanced 775 mV = 0 dBu

t10 k ohms balanced, floating

400 W (according to IEC 268-3)

25 ohms / 100V; 12.5 ohms / 70 V; 6.25 ohms / 50 V or 4 ohms / 40 V

60 Hz .. 20 kHz d 1 %

d 1.2 mV = -56 dBu electronically balanced 2 V = + 8.2 dBu

600 ohms

+5 °C .. +40 °C

483 x 132 x 345 mm max. 400 mm / 340 mm

16.7kg

anthracite

extension kits for the DPA 4120 and DPA 4140:

 

 

NRS 90208 input transformer for floating, balanced input

Art. No.

121 641

NRS 90222 remote module

Art. No.

121 674

NRS 90224 pilot tone & ground fault surveillance

Art. No.

121 676

NRS 90225 standard input module

Art. No.

121 677

NRS 90227 output transformer for floating, balanced monitor output

Art. No.

121 679

43

Page 43
Image 43
Dynacord 12.2DPA 4140 power amplifier 400 W power supply, extension kits for the DPA 4120 and DPA, mains operation