12.2DPA 4140 power amplifier 400 W power supply:
mains operation |
|
|
|
|
| 115 V / 230 V~ AC, r10 % |
|
| |||||||
mains frequency |
|
|
|
|
| 50 - 60 Hz |
|
|
|
|
|
| |||
security class |
|
|
|
|
| I |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
mains operation | Umains / V | Imains / A |
| Pmains / VA |
| Pmains / W |
| Pout / W |
| Pv / W | |||||
idling | 230 | 0.19 |
| 44 |
| 23 |
|
| 0 |
| 23 | ||||
normal operation | 230 | 1.60 |
| 368 |
| 263 |
|
| 40 |
| 223 | ||||
alarm | 230 | 3.10 |
| 713 |
| 562 |
|
| 200 |
| 362 | ||||
standard conditions | 230 | 4.43 |
| 1019 |
| 811 |
|
| 400 |
| 411 | ||||
initial current inrush (mains) |
|
| < 36 A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
mains operation | Umains / V | Imains / A |
| Pmains / VA |
| Pmains / W |
| Pout / W |
| Pv / W | |||||
idling | 115 | 0.38 |
| 44 |
| 23 |
|
| 0 |
| 23 | ||||
normal operation | 115 | 3.19 |
| 368 |
| 263 |
|
| 40 |
| 223 | ||||
alarm | 115 | 6.20 |
| 713 |
| 562 |
|
| 200 |
| 362 | ||||
standard conditions | 115 | 8.86 |
| 1019 |
| 811 |
|
| 400 |
| 411 | ||||
initial current inrush (mains) |
|
| < 21 A |
|
|
|
|
|
|
|
|
|
|
|
|
Pmains / VA = apparent power Umains* | Imains; Pmains / W = true power; Pout / W = output power; Pv / W =leakage power | ||||||||||||||
battery operation |
|
|
|
|
| 24 V DC, |
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||||||
battery operation | UB / V |
| IB / A |
| Pi / W |
| Pout / W |
| Pv / W | ||||||
24 |
| 2.5m |
| 60m |
|
|
| 0 |
| 60m | |||||
idling | 24 |
| 0.62 |
|
| 15 |
|
|
| 0 |
| 15 | |||
normal operation | 24 |
| 7.1 |
|
| 170 |
|
|
| 40 |
| 130 | |||
standard conditions | 24 |
| 17.3 |
|
| 415 |
|
| 249 |
| 166 | ||||
initial current inrush (battery) |
|
| < 3.8 A |
|
|
|
|
|
|
|
|
|
|
| |
Pi / W = input power UB*IB; Pout / W = | output power; | Pv / W = leakage power |
|
|
|
|
|
|
|
|
features of the input: nominal input level nominal input impedance features of the power output:
nominal output capacity during mains operation nominal load impedance
frequency response
distortion at 1 kHz and nominal output power interfering voltage (A)
features of the monitor output: nominal output voltage nominal load impedance
ambient temperature range dimensions (W x H x D) depth with / without connections weight without extensions finish
electronically balanced 775 mV = 0 dBu
t10 k ohms balanced, floating
400 W (according to IEC
25 ohms / 100V; 12.5 ohms / 70 V; 6.25 ohms / 50 V or 4 ohms / 40 V
60 Hz .. 20 kHz d 1 %
d 1.2 mV =
600 ohms
+5 °C .. +40 °C
483 x 132 x 345 mm max. 400 mm / 340 mm
16.7kg
anthracite
extension kits for the DPA 4120 and DPA 4140: |
|
|
NRS 90208 input transformer for floating, balanced input | Art. No. | 121 641 |
NRS 90222 remote module | Art. No. | 121 674 |
NRS 90224 pilot tone & ground fault surveillance | Art. No. | 121 676 |
NRS 90225 standard input module | Art. No. | 121 677 |
NRS 90227 output transformer for floating, balanced monitor output | Art. No. | 121 679 |
43