Chapter IV: Trouble Shooting

If the IP camera is not working properly, before you contact the dealer of purchase for help, please check the troubleshooting list here, this may help you to solve the problem by yourself and therefore saves your valuable time.

Scenario

Possible Solution

I can not connect to

a. Please confirm the IP address setting of the

IP camera

computer you‟re using. If they‟re not in the same

 

subnet, they will not be able to communicate with

 

each other.

 

b. Please make the IP address you used to connect to

 

the IP camera is correct.

 

c. If you forget the IP address of the IP camera, you

 

will have to reset it to factory default value (which is

 

192.168.2.3) by pressing „reset‟ button at the bottom

 

of the IP camera. You‟ll need a pen or pin to be able

 

to press the reset button. Press and hold reset button

 

for 5 seconds, then try to connect to the IP camera

 

with IP address „192.168.2.3‟ again.

 

d. Please make sure IP camera is correctly powered

 

(the „Power‟ LED should be on).

 

e. If you‟re trying to connect to the IP camera from

 

Internet, please make sure the port that IP camera

 

uses (Video and HTTP port, see section 2.3.1) is not

 

blocked by firewall or other software / hardware.

 

f. Contact dealer of purchase for help, if above

 

solutions do not work.

 

 

Image refreshes

a. Try a higher frame rate setting, if it‟s not 30.

very slow

 

 

b. Try a lower resolution.

 

 