0

A – Command Line Interface

 

 

Show Command

 

 

 

 

version

Displays an introductory set of information about operational attributes of the switch. This keyword is equivalent to the About keyword.

Examples The following is an example of the Show Chassis command:

SANbox2 #> show

chassis

 

Chassis Information

 

-------------------

 

BoardTemp (1)

- Degrees Celsius

32

BoardTemp (2)

- Degrees Celsius

36

FanStatus (1)

 

Good

FanStatus (2)

 

Good

PowerSupplyStatus (1)

Good

PowerSupplyStatus (2)

Good

HeartBeatCode

 

1

HeartBeatStatus

Normal

The following is an example of the Show Domains command:

SANbox2 #> show domains

 

Principal switch

is (remote): 10:00:00:60:69:50:0b:6c

Upstream Principal ISL is

: 1

Domain ID List:

 

 

Domain 97

(0x61)

WWN = 10:00:00:c0:dd:00:71:ed

Domain 98

(0x62)

WWN = 10:00:00:60:df:22:2e:0c

Domain 99

(0x63)

WWN = 10:00:00:c0:dd:00:72:45

Domain 100

(0x64)

WWN = 10:00:00:c0:dd:00:ba:68

Domain 101

(0x65)

WWN = 10:00:00:60:df:22:2e:06

Domain 102

(0x66)

WWN = 10:00:00:c0:dd:00:90:ef

Domain 103

(0x67)

WWN = 10:00:00:60:69:50:0b:6c

Domain 104

(0x68)

WWN = 10:00:00:c0:dd:00:b8:b7

The following is an example of the Show Fabric command:

SANbox2 #> show fabric

Domain

WWN

Enet IP Addr

FC IP Addr

SymbolicName

------

---

------------

----------

------------

16

(0x10)

10:00:00:c0:dd:00:77:81

10.20.68.11

0.0.0.0

gui sb1 .11

17

(0x11)

10:00:00:c0:dd:00:6a:2d

10.20.68.12

0.0.0.0

sw12

18

(0x12)

10:00:00:c0:dd:00:c3:04

10.20.68.160

0.0.0.0

sw .160

19

(0x13)

10:00:00:c0:dd:00:bc:56

10.20.68.108

0.0.0.0

Sb2 .108

59022-10 A

A-65

Page 217
Image 217
Q-Logic SANBOX2-8C/16 manual Version, Following is an example of the Show Domains command