14: Command Reference

Enter the prompt displayed by the SLP or ServerTech CDU device. This will default to a typical prompt for an SLP or ServerTech CDU. If you are unable to control the SLP or ServerTech CDU device, verify that the prompt is set to the right value.

[numoutlets <Number of Outlets>] [numexpoutlets <Number of Expansion Outlets>]

Enter the number of outlets for a ServerTech CDU main unit or the number of outlets for a ServerTech CDU expansion unit. This settings is not applicable for an SLP.

slpservertech config [prompt <Command Prompt>]

Displays the system configuration information, such as firmware, revision and uptime.

sensorsoft lowtemp <Low Temperature in C.>

Sets the lowest temperature permitted for the port.

sensorsoft hightemp <High Temperature in C.>

Sets the hightest temperature permitted for the port.

sensorsoft lowhumidity <Low Humidity %>

Sets the lowest humidity pemitted for the port.

sensorsoft highhumidity <High Humidity %>

Sets the lowest humidity permitted for the port.

sensorsoft degrees <celsiusfahrenheit>

Enables or disables temperature settings as celcius or fahrenheit.

sensorsoft traps <enabledisable>

Enables or disables traps when specified conditions are met.

sensorsoft status

Displays the status of the port.

Description

Sends commands to (or control) a device connected to an SLC device port over the serial port.

Note: Currently the only devices supported for this type of interaction are the SLP device, ServerTech CDUs, and Sensorsoft devices.

Device Port Commands

set deviceport port

Description

Sets the dialout password.

SLC™ 8000 Advanced Console Manager User Guide