3: Installation

Physical Installation

Install the SLC 8000 advanced console manager in an EIA-standard 19-inch rack (1U tall) or as a desktop unit. The SLC module uses convection cooling to dissipate excess heat.

To install the SLC 8000 advanced console manager in a rack:

1. Place the SLC unit in a 19-inch rack.

Warning: Do not to block the air vents on the sides of the SLC module. If you mount the SLC advanced console manager in an enclosed rack, we recommended that the rack have a ventilation fan to provide adequate airflow through the SLC unit.

2.Connect the serial device(s) to the SLC unit ports. See the section, Connecting to a Device Port (on page 29).

3.Choose one of the following options:

-To configure the SLC 8000 advanced console manager using the network, or to monitor serial devices on the network, connect at least one SLC network port to a network. See Connecting to Network Ports (on page 31).

-To configure the SLC unit using a dumb terminal or a computer with terminal emulation, connect the terminal or PC to the SLC console port. See Connecting Terminals (on page 31).

4.Connect the power cord, and apply power. See AC Input (on page 32).

5.Wait approximately a minute for the boot process to complete.

When the boot process ends, the SLC host name and the clock appear on the LCD display. Now you are ready to configure the network settings as described in Chapter 4: Quick Setup.

Connecting to a Device Port

You can connect almost any device that has a serial console port to a device port on the SLC 8000 advanced console manager for remote administration. The console port must support the RS- 232C interface.

Note: Many servers must either have the serial port enabled as a console or the keyboard and mouse detached. Consult the server hardware and/or software documentation for more information.

To connect to a device port:

1.Connect one end of the Cat 5 cable to the device port.

2.Connect the other end of the Cat 5 cable to a Lantronix serial console adapter.

Note: See Device Port Commands on page 115 to enable or disable reverse pinouts through the CLI. Table 3-4, Table 3-5and Figure 3-3provide additional information on reverse pinouts. Reference Appendix C: Adapters and Pinouts on page 331 for more information about Lantronix adapters.

SLC™ 8000 Advanced Console Manager User Guide

29

Page 29
Image 29
Lantronix SLC 8000 manual Physical Installation, Connecting to a Device Port, To connect to a device port