Lantronix SLC 8000 manual Telnet/SSH/TCP in Port Numbers, Global Commands

Models: SLC 8000

1 337
Download 337 pages 21.89 Kb
Page 104
Image 104

8: Device Ports

To set up Telnet, SSH, and TCP port numbering:

1. Enter the following:

Telnet/SSH/TCP in Port Numbers

Starting Telnet Port

Each port is assigned a number for connecting via Telnet. Enter a number (1025-

 

65528) that represents the first port. The default is 2000 plus the port number. For

 

example, if you enter 2001, subsequent ports are automatically assigned numbers

 

2002, 2003, and so on.

 

 

Starting SSH Port

Each port is assigned a number for connecting via SSH. Enter a number (1025-

 

65528) that represents the first port. The default is 3000 plus the port number. For

 

example, if you enter 3001, subsequent ports are automatically assigned numbers

 

3002, 3003, and so on.

 

 

Starting TCP Port

Each port is assigned a number for connecting through a raw TCP connection. Enter

 

a number (1025-65528) that represents the first port. The default is 4000 plus the

 

port number. For example, if you enter 4001, subsequent ports are automatically

 

numbered 4002, 4003, and so on.

 

You can use a raw TCP connection in situations where a TCP/IP connection is to

 

communicate with a serial device. For example, you can connect a serial printer to a

 

device port and use a raw TCP connection to spool print jobs to the printer over the

 

network.

 

Note: When using raw TCP connections to transmit binary data, or where the break

 

command (escape sequence) is not required, set the Break Sequence of the

 

respective device port to null (clear it).

 

 

Caution: Ports 1-1024 are RFC-assigned and may conflict with services running on the SLC 8000 advanced console manager. Avoid this range.

2. Click the Apply button to save the settings.

To set limits on direct connections:

1.Enter the maximum number (1-10) of simultaneous direct connections for each device port. The default is 1.

2.Click the Apply button to save the settings.

To configure a specific port:

1.You have two options:

-Select the port from the ports list and click the Configure button. The Device Ports > Settings page for the port displays.

-Click the port number on the green bar at the top of each page.

2.Continue with directions in the section, Device Ports - Settings (on page 105).

Global Commands

The following CLI commands correspond to the web page entries described above.

To configure settings for all or a group of device ports:

set deviceport global <one or more parameters>

SLC™ 8000 Advanced Console Manager User Guide