3: Installation

Technical Specifications

 

 

Table 3-2 SLC Technical Specifications

 

 

 

 

Component

Description

 

Serial Interface (Device)

(48) RJ45-type 8-conductor connectors which are individually configurable

 

 

standard or reversed pinouts

 

 

Speed software selectable (300 to 230400 baud)

 

 

Note: Device ports for the SLC 8000 advanced console manager are

 

 

reversed by default. Do not use rolled cables and adapters when replacing an

 

 

SLC 8000 advanced console manager with the SLC 8000 model.

 

 

 

 

Serial Interface (Console)

(1) RJ45-type 8-pin connector (DTE)

 

 

Speed software selectable (300 to 230400 baud)

 

 

LEDs:

 

 

Green light ON indicates data transmission activities

 

 

Yellow light ON indicates data receiving activities

 

 

 

 

Network Interface

(2) 10/100/1000 Base-T RJ45 Ethernet

 

 

LEDs:

 

 

Green light ON indicates a link at 1000 Base-T

 

 

Green light OFF indicates a link at other speeds or no link

 

 

Yellow light ON indicates a link is established

 

 

Yellow light blinking indicates activity

 

 

 

 

Power Supply AC

Universal AC power input: 100-240 VAC

 

(single or dual)

50 or 60 Hz IEC 60320/C19IEC-type regional cord set included

 

 

 

 

Power Supply DC (dual)

20V to 72V input

 

 

 

 

Power Consumption

Less than 25 watts

 

 

 

 

Dimensions

1U, 1.75 in x 17.25 in x 12 in

 

 

 

 

Weight

11.5 lbs or less, depending on options

 

 

 

 

Temperature

Operating: 0 to 50°C (32 to 122°F), 30 to 90% RH, non-condensing

 

 

Storage: -20 to 80°C (-4 to 176°F), 10 to 90% RH, non-condensing

 

 

 

 

Relative Humidity

Operating: 10% to 90% non-condensing; 40% to 60% recommended

 

 

Storage: 10% to 90% non-condensing

 

 

 

 

USB Ports

(2) ports, type A, host USB 2.0 (HS, FS, LS)

 

 

 

 

Memory Card

Single memory card slot supporting:

 

 

SD

 

 

SDHC

 

 

 

 

Modem

300 bps to 56K bps data rate

 

 

Upstream 48K bps, downstream 56K bps

 

 

V.44 data compression (V92MB-U, V92HU)

 

 

V.42 bis and MNP-5 data compression

 

 

V.29 FastPOS support

 

 

Caller ID type I and II for select countries

 

 

Agency approvals: Transferable FCC68, CS03 and CTR21 certifications,

 

 

IEC60601-1 (Medical Electronics) compliant, CE Marking, IEC60950 approved

 

 

 