Lantronix SLC 8000 USB Logging disabled, Trying Connected to Escape character is Sun OS 8.0 login

Models: SLC 8000

1 337
Download 337 pages 21.89 Kb
Page 259
Image 259

13: Application Examples

Logging Settings----------------------------------------------------

USB Logging: disabled

Local Logging: disabled

Email Logging: disabled

Log to: upper slot

Byte Threshold: 100

Max number of files: 10

Email Delay: 60

seconds

Max size of files: 2048

Restart Delay: 60

seconds

 

Email To: <none>

 

 

Email Subject: Port %d Logging

Email String: <none>

NFS File Logging: disabled

Directory to log to: <none>

Max number of files: 10

Max size of files: 2048

2.Change the serial settings to match the serial settings for the vt100 terminal - changes baud to

57600 and disables flow control:

[SLC]> set deviceport port 2 baud 57600 flowcontrol none Device Port settings successfully updated.

3.Create a connection between the vt100 terminal connected to device port 2 and an outbound telnet session to the server. (The IP address of the server is 192.168.1.1):

[SLC]> connect bidirection 2 telnet 192.168.1.1 Connection settings successfully updated.

4.At the VT100 terminal, hit <return> a couple of times. The Telnet prompt from the server displays:

Trying 192.168.1.1...

Connected to 192.168.1.1.

Escape character is '^]'.

Sun OS 8.0 login:

At this point, a user can log in and interact with the Sun server at the VT100 terminal as if directly connected to the server.

SLC™ 8000 Advanced Console Manager User Guide

259

Page 259
Image 259
Lantronix SLC 8000 manual USB Logging disabled, Trying Connected to Escape character is Sun OS 8.0 login