3 – Managing Fabrics

0

 

 

Zoning a Fabric

 

 

 

 

 

 

 

 

„MaxMembersPerAlias is 2000. The maximum number of zone members that can be added to any alias on the switch. This will be enforced during the configuration of zoning and during a zoning database merge from the fabric.

3.6.2

Using the Zoning Wizard

The Zoning Wizard is a series of dialogs that leads you through the process of zoning a fabric. To open the Zoning Wizard, open the Wizards menu in the faceplate display, and select Zoning Wizard.

The Zoning Wizard helps you zone the two most typical reasons for zoning:

„Zoning Windows servers storage

„Assign storage to servers.

To solve these problems, there must be at least one target and at least one initiator in the name server. Windows servers do not share devices well, but sometimes they must share devices, such as a tape drive. The wizard helps you define which devices are sharable and which ones are not. Once a device is in a Windows group, it can no longer be in any other group.

3.6.3

Managing the Zoning Database

Managing the zoning database consists of the following:

„Editing the Zoning Database

„Configuring the Zoning Database

„Saving the Zoning Database to a File

„Restoring the Zoning Database from a File

„Restoring the Default Zoning Database

„Removing All Zoning Definitions

3-24