4 – Managing Switches

 

 

 

 

 

 

Displaying Switch Information

 

 

 

 

 

 

 

 

 

Table 4-2. Switch Data Window Entries (Continued)

 

 

 

 

Entry

Description

 

 

 

 

Power Supply 2 Status

Power supply 2 status (SANbox2-16 only)

 

Beacon Status

Beacon status. Switch LEDs are blinking (On) or not (off).

 

Broadcast Support

Broadcast support status. Broadcast support is enabled or

 

 

disabled (default).

 

In-band Enabled

In-band management status. Permits (True) or prevents

 

 

(False) a switch from being managed over an ISL.

 

Temperature Failure Port

Non-configurable (always enabled for this switch). All

 

Shutdown

ports are downed when the switch temperature exceeds

 

 

the Failure Temperature.

 

Warning Temperature

Non-configurable temperature threshold (65° Celsius)

 

 

above which a warning condition alarm is generated.

 

Failure Temperature

Non-configurable temperature threshold (70° Celsius)

 

 

above which a failure condition alarm is generated.

 

NTP Client Enabled

Enabled or disabled. Allows for switches to synchronize

 

 

their time a centralized server.

 

NTP Server Address

The IP address of the centralized NTP server. Ethernet

 

 

connection to NTP server is required.

 

FDMI Enable

Fabric Device Management Interface status. If enabled,

 

 

device information can be obtained, managed, and saved

 

 

through the fabric using Name Service Management

 

 

Server functions. SANsurfer Switch Manager will report

 

 

any and all FDMI information reported by the entry switch,

 

 

if FDMI is enabled on the entry switch. Refer to

 

 

”Displaying Detailed Device Information” on page 3-17for

 

 

information about displaying FDMI information.

 

FDMI HBA Entry Limit

Maximum number of HBAs that can be registered with a

 

 

switch.

 

Number of Donor Groups

Total number of donor port groups. A donor group is a set

 

 

of ports on a switch that can donate buffer credits to each

 

 

other.

 

Embedded GUI

SANsurfer Switch Manager web applet status. Enables or

 

 

disables the web applet on the switch.

 

Inactivity Timeout

Number of minutes the switch waits before terminating an

 

 

idle SANsurfer Switch Manager Web applet session. Zero

 

 

(0) disables the time out threshold.

 

 

 

 

59022-10 A