A – Command Line Interface | 0 | |||
|
| |||
Set Config Command |
|
| ||
|
|
|
|
|
|
|
|
|
|
| Table | |||
|
|
|
| |
| Parameter | Description |
| |
|
|
|
| |
| LCFEnable | Link control frame preference routing. This parameter |
| |
|
|
| appears only if AutoPerfTuning is False. Enables (True) |
|
|
|
| or disables (False) preferred routing of frames with |
|
|
|
| R_CTL = 1100 (Class 2 responses). The default is False. |
|
|
|
| Enabling LCFEnable will disable MFSEnable. |
|
| MFSEnable |
| ||
|
|
| appears only if AutoPerfTuning is False. Prevents (True) |
|
|
|
| or allows (False) the interleaving of frames in a |
|
|
|
| sequence. The default is True. Enabling MFSEnable |
|
|
|
| disables LCFEnable and VIEnable. |
|
| VIEnable | Virtual Interface (VI) preference routing. This parameter |
| |
|
|
| appears only if AutoPerfTuning is False. Enables (True) |
|
|
|
| or disables (False) VI preference routing. The default is |
|
|
|
| False. Enabling VIEnable will disable MFSEnable. |
|
| MSEnable | Management server enable. Enables (True) or disables |
| |
|
|
| (False) management server on this port. The default is |
|
|
|
| True. |
|
| NoClose | Loop circuit closure prevention. Enables (True) or |
| |
|
|
| disables (False) the loop’s ability to remain in the open |
|
|
|
| state indefinitely. True reduces the amount of arbitration |
|
|
|
| on a loop when there is only one device on the loop. The |
|
|
|
| default is False. |
|
| IOStreamGuard | I/O Stream Guard. Enables or disables the suppression |
| |
|
|
| of RSCN messages. IOStreamGuard can have the |
|
|
|
| following values: |
|
|
|
| Enable – Suppresses the reception of RSCN |
|
|
|
| messages from other ports for which |
|
|
|
| IOStreamGuard is enabled. |
|
|
|
| Disable – Allows free transmission and reception of |
|
|
|
| RSCN messages. |
|
|
|
| Auto – Suppresses the reception of RSCN |
|
|
|
| messages under the following conditions: 1) The |
|
|
|
| port is connected to an initiator device with a QLogic |
|
|
|
| HBA, 2) The DeviceScanEnable parameter is |
|
|
|
| enabled. Auto is the default. |
|
| PDISCPingEnable | Enables (True) or disables (False) the transmission of |
| |
|
|
| ping messages from the switch to all devices on a loop |
|
|
|
| port. The default is True. |
|
|
|
|
|
|