You must be aware of the

following safety requirements &

regulations

Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using this
appliance.
In the UK the regulations and standards are as follows:-
In your own interest and that of safety, it is law that all
gas appliances be installed by competent persons.
CORGI registered installers undertake to work to safe
and satisfactory standards. Failure to install the appliance
correctly could invalidate any warranty or liability claims
and lead to prosecution. The cooker must be installed in
accordance with
All relevant British Standards / Codes of
Practice, in particular BS 5440 Part 2 2000,
For Natural Gas - BS 6172 : 1990 and BS
6891 : 1998
For LP Gas - BS 5482-1:1994 (when the
installation is in a permanent dwelling), BS
5482-2:1977, (when the installation is in a
caravan or other non permanent dwelling), or
BS 5482-3:1999 , (when the installation is in a
boat).
The Gas Safety (Installation and Use)
regulations 1998.
The relevant Building / IEE regulations.

Provision of Ventilation

This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to
the relevant requirements regarding ventilation.
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent, while
some rooms require a permanent vent in addition to the
openable window. The cooker should not be installed in a
bedsitting room with volume less than 20m3. If it is
installed in a room of volume less than 5m3 an air vent of
effective area 100cm2 is required; if it is installed in a
room of volume between 5m3 and 10m3, an air vent of
effective area 50cm2 is required; while if the volume
exceeds 11m3, no air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.

Location of Cooker

The cooker may be installed in a kitchen/kitchen diner but
NOT in a room containing a bath or shower.

NOTE:

An appliance for use on LPG shall not be installed in
a room or internal space below ground level. e.g. in a
basement.