FRU Information and Sensor Data Records | MAC Address Record |
|
|
addresses. The format of the record is described in the following tables.
Table 3-2 Emerson MAC Address Record
Offset | Length | Description |
|
|
|
0 | 1 | Record Type ID. A value of 0xC0 |
|
|
|
1 | 1 | End of List/Version |
|
| [7] End of List. Set to 01b for the last record |
|
| [6:4] Reserved. Write as 0b0000. |
|
| [3:0] Record format version. Write as 0x2. |
|
|
|
2 | 1 | Record Length |
|
|
|
3 | 1 | Record Checksum. Holds the zero checksum of the record |
|
|
|
4 | 1 | Header Checksum. Holds the zero checksum of the header. |
|
|
|
5 | 1 | LSB of Manufacturer ID. Value is 0xCD |
|
|
|
6 | 1 | Second Byte of Manufacturer ID. Value is 0x65 |
|
|
|
7 | 1 | MSB of Manufacturer ID. Value is 0x00 |
|
|
|
8 | 1 | Emerson Record ID. Value is 0x01 |
|
|
|
9 | 1 | Record Format Version. Value is: 0x00 |
|
|
|
10 | 1 | Number of MAC Address Descriptors (N). |
|
|
|
11 | N*7 | Emerson MAC Address Descriptors |
|
| Refer to Table |
|
| Descriptor. |
|
|
|
Table 3-3 Emerson MAC Address Descriptor
Offset | Length | Description |
|
|
|
0 | 1 | Interface type |
|
| Refer to Table |
|
|
|
1 | 6 | MAC Address. First octet comes first. |
|
|
|
Table 3-4 Interface Type Assignments
Interface Type | Description |
|
|
0x01 | AdvancedTCA base interface or AMC/MicroTCA common options region |
|
|
0x02 | AdvancedTCA fabric interface or AMC/MicroTCA fat pipe region |
|
|
0x03 | Face plate |
|
|
0x04 | AMC/MicroTCA extended fat pipe region |
|
|
28 |