SOL Module Configuration

4

4.1Introduction

This chapter includes the following sections:

zConfigure the SOL

zEnable SOL load

zSetup a SOL session

zQuery the configuration of SOL

zConfigure the SOL mode in OS

4.2Configure the SOL

Before the configuration, the IPMC has no user or IP address, so you cannot connect to the IPMC through IPMITOOL. In this case, you need to use IPMI commands through the IPMB channel of the shelf managers to configure the SOL and set the IPMC.

The IPMB address is the hardware address marked on the shelf multiplied by 2.

Configuring SOL

Perform the following six steps to configure the SOL:

1.Set the IP addresses of the two channels.

Use the command Set LAN Configuration Parameters of IPMI2.0 with Parameter selector of 3.

See table 23-2 in section 23.1 of the IPMI 2.0 specification. The value of Parameter selector is 3.

For example, on Emerson shelf manager, set the IP address of channel 1 to

172.17.10.78and that of channel 2 to 172.18.10.78. ipmicmd -k "0 90 0 0c 01 01 03 ac 11 0a 4e" smi 0 ipmicmd -k "0 90 0 0c 01 02 03 ac 12 0a 4e" smi 0

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)

53