Serial Output Commands

Supported Commands

 

 

2.3.1.2.1Request Data

The following table lists the request data applicable to the Get Serial Output command.

Table 2-18 Request Data of Get Serial Output Command

Byte

Data Field

 

 

1

LSB of Emerson IANA Enterprise number. A value of 0xCD has to be used.

 

 

2

Second byte of Emerson IANA Enterprise number. A value of 0x65 has to be used.

 

 

3

MSB of Emerson IANA Enterprise number. A value of 0x00 has to be used.

 

 

4

Serial connector type

 

0: Face plate connector

 

All other values are reserved.

 

 

5

Serial connector instance number. A sequential number that starts from 0.

 

 

2.3.1.2.2Response Data

The following table lists the response data applicable to the Get Serial Output command.

Table 2-19 Response Data of Get Serial Output Command

Byte

Data Field

 

 

1

Completion code

 

 

2

LSB of Emerson IANA Enterprise number.

 

 

3

Second byte of Emerson IANA Enterprise number.

 

 

4

MSB of Emerson IANA Enterprise number.

 

 

5

Serial output selector

 

 

ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)