2.2Surface-Mounting the Liqui-tect Panel

Installation

2.2Surface-Mounting the Liqui-tect Panel

NOTE

Removing the conduit knockouts before mounting the Liqui-tect panel on the wall will ease installation and prevent strain on the mounting hardware and wall. It is imperative to remove the knockouts if the unit is to be flush-mounted.

After determining where to place the unit, check to ensure that you have all the hardware required to install the panel on the surface of a wall. Obtain the needed tools and material.

Required tools

• Electric drill (if surface is too hard to drive screws without pilot holes)

• Screwdriver

• Marker to denote layout of holes

• Four screws, each #10

2.2.1 Mounting the Panel

! CAUTION

Check building plans and other relevant documents to determine whether mounting the Liqui-tect panel at the selected location might cause cutting or otherwise damaging electrical or communication wiring or pipes.

1.Mark the wall for mounting holes, using the back of the unit as a template (see Figure 4).

2.Drill holes, if required, to install the four #10 screws that will secure the Liqui-tect panel to the wall. Clean up the debris.

3.If the wall material is not strong enough to hold the screws securely, use wall anchors.

4.Install the top two screws—the screw heads must be small enough to slip through the larger, bottom portion of the pear-shaped mounting slot in the Liqui-tect panel (see inset in illustration at right). The screws must also be large enough to extend over the edges of the top of the mounting slot.

5.Hang the Liqui-tect panel on the screws, letting the panel slip down until the screws are in the smaller, upper portion of the slot.

6.Tighten the screws until they are snug.

7.Insert the remaining two screws in the bottom holes on the back of the panel and tighten.

Figure 4 Mounting dimensions

 

 

LARGE ENCLOSURE

 

 

12"

 

 

(304.8mm)

SMALL ENCLOSURE

 

 

12.5"

0.213"

 

(317.5mm)

 

 

(5.4mm)

0.213"

 

16"

(5.4mm)

 

10"

(406.4mm)

 

Liqui-tect panel

 

(254mm)

 

back plate

 

 

 

Liqui-tect panel

 

 

back plate

0.375"

 

 

 

 

(9.6mm)

 

 

Mounting Slot

0.375"

 

 

(9.6mm)

 

 

Mounting Slot

0.213" (5.4mm)

0.213" (5.4mm)

 

 

Bottom hole diameter

Bottom hole diameter

8