5.1View Cable Status

View Status Options

5.1View Cable Status

The Cable Status screens display the overall status of the cable con- nected to each of the two zones monitored by the Liqui-tect panel, as well as the length of the cable being monitored and the amount of cur- rent present in each cable.

To view the status of the cable:

• From the Main Menu, use the arrows ↑↓ to choose View Status, as shown at right, and then press Enter .

• From the View Status Menu, use the arrows ↑↓ to choose View Cable Status and press Enter .

5.1.1Cable Status Screens

Each Cable Status screen displays the zone name (ZN1 or ZN2) and its label (for example, ZONE 1 or ZONE 2) at the top.

Viewing Additional Screens

There are four Cable Status screens—two for each zone.

To view additional screens, use the arrows ↑↓ .

To return to the previous screen, press the ESC key.

When finished viewing the last screen, press Enter .

Overall Condition

The first screen for each zone shows:

the zone name (ZN1 or ZN2) and its label (for example, ZONE 1 or

ZONE 2)

the current overall condition of the cable (for example, NORMAL)

The cable conditions tracked by the Liqui-tect panel appear in Table 5.

Table 5 Overall cable conditions

SOURCE

Cable

CONDITIONS

NORMAL

RECORDED

CABLE BREAK

 

LEAK DETECTED (& location, e.g., LEAK @ 99 FT)

 

CONTAMINATED (& location, e.g., CONTAM @ 44 FT)

 

NOT INSTALLED

Main Menu

>VIEW STATUS SYSTEM AND CONTROL

↑↓ =NEXT

=SELECT

View Status Menu

>VIEW CABLE STATUS VIEW ALARM HISTORY

VIEW ZONE TREND

↑↓ =NEXT

=SELECT

Overall Condition (ZN1)

STATUS ZN1 ZONE 1

NORMAL

↑↓ =NEXT

Length & Current (ZN1)

STATUS ZN1 ZONE 1

LENGTH:

1000FT

CURRENT:

0UA

↑↓ =NEXT

=DONE

Overall Condition (ZN2)

STATUS ZN2 ZONE 2

NORMAL

↑↓ =NEXT

Length & Current (ZN2)

STATUS ZN2 ZONE 2

LENGTH:

3500FT

CURRENT:

0UA

↑↓ =NEXT

=DONE

Cable Length & Current Value

The second screen for each zone shows:

the zone name (ZN1 or ZN2) and its label (for example, ZONE 1 or ZONE 2)

the length of cable being monitored (for example, 1000FT)—this value may change dynamically by up to 0.5% as the panel is continuously calculating the distance of the connected cable

the current reading (0UA, where UA represents µA or microAmps)