| Troubleshooting Checklist |
|
| Table |
| ||
|
|
|
|
|
| Problem | Possible Cause | Recommended Action |
|
|
|
|
|
|
| Cannot contact the | IP address not assigned. | Refer to the SecureStack A2 |
|
| SecureStack A2 |
| Configuration Guide for the IP address |
|
| through |
| assignment procedure. |
|
| management. |
|
|
|
| Port is disabled. | This is normal if the switch is a Member in |
| |
|
|
| ||
|
|
| a stack. |
|
|
|
| If operating as a standalone switch or as |
|
|
|
| the Manager in a stack, enable the port. |
|
|
|
| Refer to the SecureStack A2 |
|
|
|
| Configuration Guide for instructions to |
|
|
|
| enable/disable ports. |
|
|
|
|
|
|
|
| No link to switch. | Verify that all network connections |
|
|
|
| between the network management station |
|
|
|
| and the device are valid and operating. |
|
|
|
| If the problem continues, contact |
|
|
|
| Enterasys Networks for technical support. |
|
|
|
|
|
|
| Port(s) goes into | Loop condition detected. | Verify that Spanning Tree is enabled. |
|
| standby for no |
| Refer to the SecureStack A2 |
|
| apparent reason. |
| Configuration Guide for the instructions to |
|
|
|
| set the type of STA. |
|
|
|
| Review the network design and delete |
|
|
|
| unnecessary loops. |
|
|
|
| If the problem continues, contact |
|
|
|
| Enterasys Networks for technical support. |
|
|
|
|
|
|
| User parameters (IP | Clear NVRAM was set using | Reenter the lost parameters as |
|
| address, switch and | CLI commands. | necessary. Refer to the SecureStack A2 |
|
| module name, etc.) |
| Configuration Guide for the instructions to |
|
| were lost when the |
| configure the SecureStack A2 using CLI |
|
| SecureStack A2 |
| commands. |
|
| power was cycled. |
| If the problem continues, contact |
|
|
|
|
|
Enterasys Networks for technical support.
SecureStack A2 Installation Guide