Using LANVIEW
4-4 Troubleshooting
26/Stack
Down Off No valid connection to switch
stackup connector. 1. Make sure the switch connected to the
stackup connector is powered on.
2. Replace cable with a known good one.
3. If the problem still exists, contact
EnterasysNetworks for technical
support.
Green Solid. Valid connection to
switch stackup connector.
Flashing. Information is being
transferred via the stacking
cable.
None.
25/Stack
Up Off No valid connection to switch
stackdown connector. 1. Make sure the switch connected to the
stackdown connector is powered on.
2. Replace cable with a known good one.
3. If the problem still exists, contact
EnterasysNetworks for technical
support.
Green Solid. Valid connection to
switch stackdown connector.
Flashing. Information is being
transferred via the stacking
cable.
None.
Manager Off Switch is operating as a
Member in the stack. None.
Green Solid. Switch is operating as
the Manager of the stack. None.
Table 4-1 LANVIEW LEDs (continued)
LED Color State Recommended Action