Spark will not light

Trouble Shooting

 

 

 

 

 

 

Possible Cause

 

 

 

Solution

 

 

 

 

 

 

 

 

 

Spark will not light

Air in the pilot supply line.

• Purge the line or start ignition several times.

the pilot after

 

 

 

 

 

 

 

 

 

 

 

No spark at pilot burner

 

• Check spark gap.

 

 

repeatedly pressing

 

 

 

 

 

 

 

• Check wiring connections to ignitor.

the spark ignitor.

 

 

 

 

 

 

 

• Check for spark in location along cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve.

 

 

 

 

 

• Replace the valve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Over tightened

 

 

 

• Replace the valve and thermocouple interrupter.

 

 

 

 

 

 

thermocouple interrupter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receiver

 

 

 

 

 

• Replace the receiver and reset the receiver’s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

code, refer to MAINTENANCE AND SERVICE -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANGING REMOTE HANDSET CODE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot is lit and

 

 

Receiver.

 

 

 

 

 

• Replace the receiver and reset the receiver’s

control continues

 

 

 

 

 

 

 

 

code, refer to MAINTENANCE AND SERVICE -

to spark. Valve

 

 

 

 

 

 

 

 

 

CHANGING REMOTE HANDSET CODE.

shuts off after 10 to

 

 

 

 

 

 

 

 

 

 

 

 

30 seconds. Valve

 

 

 

 

 

 

 

 

 

 

 

 

operates manually.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot

 

is

lit

and

Not

enough

voltage

• Use a digital multimeter set in the mV range

sparking stops. Valve

generated

 

from

 

 

the

 

and measure the voltage by touching one test

shuts off after 10 to

thermocouple or too much

 

lead to the metal body of the valve and the

60

seconds.

Valve

resistance in the circuit.

 

 

other lead will go to the spade connector of the

does

not

operate

Note: To find which part of

 

thermocouple line (see Figure 82). The available

manually.

 

 

 

the

circuit

is

causing

the

 

voltage must be at least 5mV. Drop time can

 

 

 

 

 

 

 

be measured after the thermocouple is fully

Note:

For

manual

problem,

a

checklist

for

 

 

heated; more than 15 seconds for the drop time

operation

turn

the

each

application

can

be

 

 

is good.

 

 

valve

knob

to

the

prepared

using an

Excel

 

 

 

 

 

 

 

 

manual

position

calculation

available

from

 

 

 

 

 

and

hold the

safety

Mertik Maxitrol.

 

 

 

 

 

 

 

 

magnet

 

 

open

Possible parts are: ON-

 

 

 

 

 

with

 

a

pen

for

OFF

switch,

Temperature

 

 

 

 

 

approximately

60

switches,

Thermo

current

 

 

 

 

 

seconds (see

Figure

connections, Receiver.

 

 

 

 

 

 

 

91).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 81: Valve’s

Figure 82: Voltage Across

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Magnet.

Valve & Spade.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermocouple.

 

 

 

• Replace the thermocouple.

 

 

 

 

 

 

Low inlet pressure.

 

 

 

• Confirm the regulator’s pressure and sizing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve.

 

 

 

 

 

• Replace the valve. Do not over tighten the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thermocouple interrupter.

 

 

 

 

 

 

BV Only: Spill switch at

• Correct cause of trip and reset switch.

 

 

 

 

 

 

the draft hood may have

 

 

 

 

 

 

 

 

 

 

 

tripped.

 

 

 

 

 

 

 

 

 

 