3. Remove the log set and all ember material.

Secondary Installation

OPTIONAL CAST ANDIRON & GRATE:

Hook the Andiron assembly over the two (2) bushings at either side of the bottom of the Sonnet (see Figure 68) and snap them firmly down into place. When in place it will look similar to the image on the front cover of this Sonnet Owner’s Manual.

Note: The mounting brackets may need to be adjusted to fit onto the bushings. Loosen the screws on the brackets, adjust the brackets, and then re-tighten the screws.

BRICK PANEL INSTALLATION:

Figure 68: Hook Placements.

NOTE: The brick liner is fragile and should be handled gently.

1.Ensure the Sonnet is turned off and allow the unit to cool.

2.Remove the glass door as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.

Warning: Do not touch or attempt to remove the glass if the fireplace is not completely cold. Never operate the fireplace with the glass removed.

3. Remove the log set and all ember material.

 

4.

Choose which brick pattern you would like to face

 

 

out.

 

5.

There is a ledge at the back of the firebox (see

 

 

Figure 69). Place the back brick panel on the ledge

 

 

and ensure the panel is flush at the bottom and top

 

 

(refer to Figure 70). Do not push at the center of the

 

 

panel.

 

6.

Slide the front of the left brick panel into the left lip

 

 

at the front of the firebox. Ensure the panel is flush to

 

 

Figure 69: Back Brick Panel Ledge.

 

the side of the firebox and the back brick panel while

 

 

 

still being hooked behind the front lip (refer to Figure 71). Take care to not bump the brick panel on

 

the burner.

 

7.Repeat step 6 for right brick panel.

8.Install the log set and ember material (refer to SECONDARY INSTALLATION - LOG SET AND EMBER INSTALLATION) and the glass door.

 

 

 

Figure 70: Back Brick Panel in Place.

 

Figure 71: Side Brick Panels in Place.

34