5.3 UNIT REPAIR - C137 PSB/PSE BOARD
This section describes problems related to the power supply board (C137 PSB/PSE). The table
below provides various symptoms, likely causes, and checkpoints. The checkpoints refer to
waveforms, resistances, and other values to check to evaluate the operation of each component.
Table 5-5. Repair of the C137 PSB/PSE
Symptom Condition Cause Checkpoint Solution
The printer
does not
operate at all.
+35 V line is
dead.
Transformer coils
are open. Check the transformer coils using a
multimeter. Replace T1.
Switching FET
(Q1).
Check the waveform at the drain
of Q1.
Replace Q1.
+35 V line is
abnormal. ZD52, Q83, or
PC1 is dead.
Check the voltage level of the
collector side. The correct
voltageisasfollows:
Power Switch Off = +1.8 VDC
Power Switch On = 0 VDC
Replace
ZD52, Q82,
or PC1.
+5 V line is
dead.
+35 V line is dead. Check the +35 V line.
Replace
IC51.
IC51 is dead.
Check the oscillation waveform
and switching waveform of IC51.
Oscillation waveform (IC51, pin 5)
Switchingwave form (IC51, pin 8)
Auto capping
operation is
invalid.
+35 V line is
invalid when
power is off.
IC81 is dead. Turn off the printer and checkthe
voltageatpin1ofIC81.
Normal voltage = 0 VDC
Replace
IC81.
C82isdeador
R88 is short.
Turn off the printer and checkthe
voltage at plus side of C82.
Normal voltage = 2.5 VDC
R88 resistance = 100 ohms
Replace
C82 or R88.
Stylus Pro XL Troubleshooting
Rev. -A 5-9