5.4 UNIT REPAIR - C162 MAIN BOARD
This section describes the problems related to the main controller board (C162 MAIN). The table
below provides various symptoms, likely causes, and checkpoints. The checkpoints refer to
waveforms, resistance, andother valu es to be checked toe valuate the operation of each component
Table 5-6. Repair of the C162 MAIN
Symptom Condition Cause Checkpoint Solution
The
printer
does not
operate at
all.
The CPU
does not
operate.
(Drive
system does
not operate
normally
when you
turn the
printer on or
off.)
The reset circuit
does not operate.
Check the waveformof the +5 V
line and that of the RESETsignal.
Replace IC13
or IC8.
Selection of
control ROM is
abnormal.
Check pin 2 of IC3 for a change
in the signal HIGH/LOW.
Replace IC1.
Either CG or
RAM is defective. Replace CG
or RAM.
CPU is defective.
Check the oscillator signal at
eitherpin75or74oftheCPU.
If signal is
detected,
replace CPU.
Otherwise
replace CR1.
The
carriage
does not
operate
normally.
The carriage
motor does
not operate
at all.
IC2 is defective.
Check the serial signal output
frompin25or27ofIC2to
the driver IC15.
Replace IC2.
CPU is defective. Replace CPU.
Troubleshooting Stylus Pro XL