1.2.5 Electrical SpecificationsTable 1-7. Rated Electrical Ranges
Specification 120 V Version 220 - 240 V Version
Rated voltage 120 VAC 220 - 240 VAC
Input voltage range 103.5 ∼132 V 198 ∼264 V
Rated frequency range 50 ∼60 Hz 50 ∼60 Hz
Input frequency range 49.5 ∼60.5 Hz 49.5 ∼60.5 Hz
Rated current 0.6 A 0.4 A
Power consumption Approx.20 W
(self-test with 10-cpi LQ characters) Approx.20 W
(self-test with 10-cpi LQ characters)
Insulation resistance 10 MΩ, minimum
(applying 500 VDC between AC line
and chassis)
10 MΩ,minimum
(applying 500 VDC between AC line
and chassis)
Dielectric strength 1000 VAC rms - 1 minute or
1200 VAC rms - 1 second
(between AC line and chassis)
1500 VAC rms - 1 minute
(between AC line and chassis)
1.2.6 Environmental ConditionsTable 1-8. Acceptable Environmental ConditionsCondition Operating Non Operating
Temperature 10 ∼35°C(50∼95°F) *1 −20 ∼60°C(−4∼122°F) *2
Humidity 20 ∼80% RH *1,3 5∼85% RH *2,3
Shock resistance 1G (within 1 msec.) 2G (within 2 msec.) *2
Vibration resistance 0.15 G 0.50G 2
*1
: For printer operation, conditionsmust be in the range shown in the figure below.
*2
: These conditions are applicablewhen the printer is in its shipping container.
*3
: Without condensation.
80%
55%
20%
27˚C 35˚C
Humidity
(% RH)
Guaranteed
(50˚F)
(80˚F)
(95˚F)
˚C
(˚F)
Figure 1-6. Temperature / Humidity RangeProduct Description Stylus Pro XL
1-8 Rev.A